24
RESET
WATER
System pressure safety
The system pressure is controlled electronically
and must be kept between 0.5 and 2.3 bar. If this
is not so the heat stove goes into alarm mode and
the display will read “
Alar Press
”.
Check system pressure, holding button for a
few seconds: the upper display will read the figure
in bar.
In any case the safety valve prevents exceeding
2.5 bar, by automatically venting the excess water
outside.
Action in the event of danger
In the event of a fire, disconnect electric power,
use an approved fire extinguisher and, if needed,
call the Fire Brigade. Then contact the Authorised
Service Centre.
Failed ignition
If no flame develops during the ignition stage or
the flue gas temperature does not reach an ade
-
quate level in the time interval set for ignition, the
stove in set to extinction and the display reads
“Alar No Acc”.
Press the "On/Off" key to reset the alarm. Wait for
the cooling cycle to be complete, clean the burn
pot and proceed with a new ignition.
Extinction during working phase
This occurs when the stove unexpectedly goes
out during normal operation (for instance becau-
se pellets in the tank have run out or due to a pel-
let filling gearmotor fault).
The stove continues operating until it processes
any pellets in the burn pot, after which the display
reads “Alar No Fire” and the stove enters extin
-
ction mode.
Press the "On/Off" button to reset the alarm. Wait
for the cooling cycle to be complete, clean the
burn pot and proceed with a new ignition.
These alarms remind you that before performing
ignition, one must ensure the burn pot is comple-
tely free, clean and correctly placed.
Power outage
Should there be a power outage for a period lon-
ger than one minute, the heat stove might emit a
minimal amount of smoke in the house: this does
not pose any risk for safety.
When the power supply is restored, the heat sto-
ve will display the words “Cool Fire”. After com
-
pleting the cooling cycle, the stove will automa-
tically restart and go into the work mode prior to
the power outage.
Electrical device faults
Manual reset thermostat
Do not try igniting the heat stove before
the required time, as it might lock down.
In the event of lock turn off the switch
at the rear of the heat stove for 1 minute, turn
it on again and wait 10 minutes before igniting
again.
The power outlet where the heat stove is
plugged in must be fitted with "earthing
connection according to regulations in
force". The Manufacturer disclaims any liability
for damage to property and harm to people