10
PLEASE NOTE:
- the appliance must be installed by a qualified
technician possessing the technical-
professional requirements according to
Ministerial Decree 37/2008 who, under their
own responsibility, shall assure compliance with
the standards according to good workmanship.
- the boiler must be connected to a central heating
system and/or domestic hot water production
network compatible with its efficiency and
output.
- all national, regional, provincial and municipal
laws and regulations in force in the country
where the appliance is installed must also be
taken into account.
- ensure the floor is not flammable: if required
use a suitable platform.
- in the room where the heat generator is
to be installed there must not be any pre-
existing hoods with extractor or collective type
ventilation ducts, nor may they be installed.
Should these appliances be in rooms next to
and communicating with the installation room,
it is forbidden to simultaneously use the heat
generator, if there is a risk that one of the two
rooms might be in a vacuum with respect to the
other.
- installation in bedrooms or bathrooms is not
admissible.
- for water connections (see next chapter) it
is recommended to use flexible pipes where
possible.
Distance from objects
It must be possible to inspect the heat stove from
all sides, hence a distance of at least 40 cm on
the rear and sides must be complied with. It is
also recommended to keep the pellets and all
flammable materials at an adequate distance
Operating premises
40 cm
40 cm
40
c
m
10
0
cm