background image

Specialists in fireplace design and manufacture

TEMPO 3 VER 2 FREESTANDING

INSTALLATION & OPERATING INSTRUCTIONS

IMPORTANT:

INSTALLER, PLEASE LEAVE THESE INSTRUCTIONS WITH THE UNIT ON COMPLETION.

10 YEAR FIREBOX WARRANTY

The firebox is covered by a 10 year warranty. 

Other parts are covered by a one year limited warranty.

Head Office 

13 French Avenue, Brendale, Queensland 4500

Telephone 

PH: (07) 3490 5500

Facsimile 

FAX: (07) 3490 5520

Website: -

www.jetmaster.com.au

Business hours: - Monday to Thursday 7:30am-4:00pm. Friday 7:30am-2:00pm

Email: -

[email protected]

Summary of Contents for TEMPO 3

Page 1: ...IT ON COMPLETION 10 YEAR FIREBOX WARRANTY The firebox is covered by a 10 year warranty Other parts are covered by a one year limited warranty Head Office 13 French Avenue Brendale Queensland 4500 Telephone PH 07 3490 5500 Facsimile FAX 07 3490 5520 Website www jetmaster com au Business hours Monday to Thursday 7 30am 4 00pm Friday 7 30am 2 00pm Email sales jetmaster com au ...

Page 2: ...DIMENSIONS TEMPO 3 VER 2 FREESTANDING UNIT A A B C D E F G H MEASUREMENTS 602 420 678 632 343 509 646 246 D B C E F 21 08 2020 Ver 7 2 G H ...

Page 3: ...DIMENSIONS TEMPO 3 VER 2 FREESTANDING UNIT A D B C E F 21 08 2020 Ver 7 3 A B C D E F G MEASUREMENTS 602 420 678 632 296 532 580 G ...

Page 4: ...21 08 2020 Ver 7 4 A D C B A B C D MEASUREMENTS 391 817 420 602 DIMENSIONS TEMPO 3 VER 2 FREESTANDING UNIT WITH MERIDIAN TABLE ...

Page 5: ...IMPORTANT BAFFLE PLATE MUST BE PULLED FORWARD TOWARDS THE FRONT OF THE BOX UPON INSTALLATION AND BEFORE OPERATION CHAMFERED BAFFLE PLATE CORNERS TO BE POSITIONED ON THE FRONT LEFT AND FRONT RIGHT CORNERS ONLY MAKE SURER THERE ARE GAPS EITHER SIDE OF THE BAFFLE PLATES ...

Page 6: ...IDES SLIDE THE BAFFLE PLATE ON A SLIGHT ANGLE TOWARDS THE BACK OF THE UNIT MAKE SURE TO PLACE ABOVE THE AIR TUBE PUSH BACK AS FAR AS POSSIBLE ALSO CHAMFERED BAFFLE PLATE CORNERS MUST BE ON THE FRONT LEFT AND FRONT RIGHT CORNER OF THE APPLIANCE PUSH THE BAFFLE PLATE SIDE WAYS UNTIL IT IS AGAINST THE SIDE WALL THEN PULL IT FORWARD AND LET IT REST ON THE FRONT TAB THIS WILL ALLOW FOR MORE ROOM FOR TH...

Page 7: ...opening and 250mm to the sides The unit must be positioned centrally to the hearth When installed with an additional 900mm high x 180 deg stainless steel rear flue shield fitted between the decromesh casing and the active flue the rear wall clearance can be reduced to 150mm from a combustible wall Clearances to combustibles as per AS NZS 2918 755 300 800 125 125 755 300 800 ...

Page 8: ...ue pipes must be connected with pop rivets supplied by installer Flue system to be installed to suit AS NZS 2918 2001 50 Vented cap B Support outer flue with Brackets supplied Bracing supplied by installer NOTE When Decromesh Heatshield is fitted it must finish a minimum of 600mm below the ceiling or extend through the ceiling drop box into the outer flue casing 9 Flue All 4 5 assembled flues must...

Page 9: ...st be connected with pop rivets supplied by installer Flue system to be installed to suit AS NZS 2918 2001 50 Vented cap B Bracing supplied by installer All casing flue pipes must be connected with pop rivets supplied by installer 12MM AIR GAP 7 Decro 7 Flue 4 5 Flue NOTE When Decromesh Heatshield is fitted it must finish a minimum of 600mm below the ceiling or extend through the ceiling drop box ...

Page 10: ...20 Ver 7 3000 OR LESS INCREASE FROM 1000 MIN UNTIL CLEAR WITHIN 3000 OF TOP OF FLUE 3000 ANY NEARBY STRUCTURE 6000 MORE THAN 3000 600 MIN 3000 1000 MIN IF CLEAR WITHIN 3000 OF TOP OF FLUE INCREASE AS NECESSARY UNTIL NOTHING WITHIN 6000 OF THE FLUE TOP 600 MIN 3000 OR LESS MORE THAN 3000 DIMENSIONS IN MILLIMETRES ...

Page 11: ...21 08 2020 Ver 7 11 ...

Page 12: ...mately 10 to 15 minutes until the new pieces are burning well then it may be returned to its desired setting 6 To set the fire for overnight burn two thirds fill the firebox with hardwood and fully open the air inlet Once the fire is burning well the air inlet control should be shut down approximately three quarters of its travel Setting the air inlet control may be varied to suit your particular ...

Page 13: ... with higher heat production than wet or green wood The difference between the amount of heat produced by dry wood and green wood is so great that a dry softwood of good grade will produce more heat than green hardwood Green white ash for instance is not as good a fuel as dry tamarack The reason for the superiority of dry wood is easy to understand Heat cannot be produced until moisture has been d...

Page 14: ... of inspection for damaged heater 5 CLAIMS 5 1 I Kemlan will provide a full replacement of the heater in the first five years after installation ii Replacement in the subsequent five years i e sixth to tenth year after installation will be on the following basis Owner will pay fifty percent of the current retail price if the claim is made in the sixth year tenth year after purchase 5 2 Replacement...

Reviews: