Page 1: ...1 1 r 6 1 N r CARACTÉRISTIQUES TECHNIQUES GAZ PRESSION INJECTEUR DÉBIT DÉBIT UTILISÉ NOMINAL RÉDUIT Gaz Naturel 20 MBAR diam 2 46 720UH 200 UH Réf 700 Gaz Propane 37MBAR diam 1 59 280UH 100UH Réf 240 PUISSANCE UTILE 6kW 6kW DESCRIPTION Dimensions Height 595 mm 23 5 inches Width 645 mm 25 5 inches Depth 318 mm 112 5 inches Rear flue outlet diameter 125 mm 5 inches Piezo electric ignition Outside Ca...

Page 2: ...ille d accès à la manette gaz Fig 4 INSTALLATION Fix flue spigot tc rear of steve The installation of the appliance connection tc the flue connection tc the gas supply servicing or any adjustment must be carried out by aqualified gas fitter The installation of the appliance must be in accordance with the relevant requirements of the current Gas Safety Installation and Use Regulations Building Regu...

Page 3: ...ais en ménageant des espaces entre elles Condamner ensuite la porte de l appareil à l aide de la vis fournie Fig 5 3 FITTING THE LOWER BAFFLE Put the baffle under the steve so that its fixture heles face the four visible screws and fasten with the nuts supplied Fig 3 INSTALLATION OF THE LOG SET First put 4logs onto the support without forgetting to leave sufficient space between them Lock the door...

Page 4: ...lacée la manette du thermostat est atteinte le thermostat module c est à dire fait varier la quantité de gaz admise au brûleur de façon à maintenir la température désirée Les marques de 1 à 6 figurant sur la manette sont des repères Al aide d un thermomètre placé dans le local il est facile de placer la manette sur le repère qui donne la température désirée Après un certain temps d utilisation de ...

Page 5: ...place et procéder aux vérifications Régler éventuellement la valeur du débit réduit la vis de réglage est placée sous l Index du thermostat et en bas 5 TURNING THE BURNER OFF HONEYWELL VALVE Rotate the ignition knob clockwise until the arrow points at the off po sition point CONVERSION TO L P G This operation MUST be carried out be a qualified Installer who must check thal the flame burns satisfac...

Page 6: ...s REPLACEMENT PARTS SERVICING If alter many years of satisfactory service the replacement of certain parts becomes necessary contact your SUPPLIER or any of our APPOINTED AGENTS Give him the details on the INFORMATION PLATE at the BACK OF THE APPLIANCE or on the WARRANTY VOUCHER which must be kept even once the guarantee no longer applies As he holds the nomenclatures and ail the technical documen...

Page 7: ...re réfractaire 18816344400 3 3144 loquet de fermeture 12839314411 4 AA vis épaulement TF fendue 00001305233 5 3451 F écusson GODIN 18501345111 6 AA rivet acier TR 6x30 00001301998 7 3144 F porte foyer préciser la couleur 128613144 3444 AF ficelle céramique tressée porte foyer 18814344400 8 3144 F façade préciser la couleur 121013144 Eclaté du corps 16 14 j 18 l 1 21 25 26 7 www pieces de poele com...

Page 8: ...001306234 37 AA raccord laiton N1 2 61 3 8 12 1 2 00001306213 38 AA dérivation 00001306023 39 3444 AF tube alimentation 15230344400 40 AA thermostat DAT chauffage 00001305918 41 AA injecteur veilleuse GP N1 2 46 00001305102 AA injecteur veilleuse GN 00001305497 41 l l Société Anonyme au capital de 1 562 820 GODIN 02120 GUISE FRANCE Tél 33 03 23 05 70 00 Fax usine 33 03 23 60 41 05 Fax SAV 33 03 23...