Programming Manual UTG1000X Series
Instruments.uni-trend.com
21
/
51
:CHANnel<n>:PM:PHASe:DEV
Syntax
:CHANnel<n>:PM:PHASe:DEV { <phase>}
:CHANnel<n>:PM:PHASe:DEV?
Description
Set the phase deviation for the specified channel output.
<phase> represents phase deviation, the unit is°, the range is 0~360.
<n>: Channel number, n takes value 1, 2.
Return Format
The query returns the phase deviation for the specified channel output.
For Example
:CHANnel1:PM:PHASe:DEV 30
Set phase deviation for CH1 to 30°.
:CHANnel1:PM:PHASe:DEV?
The query returns 30.
:CHANnel<n>:PWM:DUTY:DEV
Syntax
:CHANnel<n>:PWM:DUTY:DEV {<duty>}
:CHANnel<n>:PWM:DUTY:DEV?
Description
Set the duty cycle deviation under PWM mode for the specified channel.
< duty > represents duty cycle deviation, the unit is %. The range is 0-100.
<n>: Channel number, n takes value 1, 2.
Return Format
The query returns the duty cycle deviation under PWM mode of the specified channel in scientific notation.
For Example
:CHANnel1:PWM:DUTY:DEV 10
Set duty cycle deviation for CH1 to 10%.
:CHANnel1:PWM:DUTY:DEV?
The query returns 1.e+1.
:CHANnel<n>:FSK:FREQuency
Syntax
:CHANnel<n>:FSK:FREQuency { <freq>}
:CHANnel<n>:FSK:FREQuency?
Description
Set the hopping frequency of FSK for the specified channel. The modulation mode must be specified in
advance for this command to take effect.
< freq > represents frequency, the unit is Hz.
<n>: Channel number, n takes value 1, 2.
Return Format
The query returns the hopping frequency of FSK for the specified channel in scientific notation.
For Example