Programming Manual UTG1000X Series
Instruments.uni-trend.com
11
/
51
:CHANnel<n>:LIMit:LOWer
Syntax
:CHANnel<n>:LIMit:LOWer {<voltage>}
:CHANnel<n>:LIMit:LOWer?
Description
Set the lower limit of amplitude for the specified channel.
<voltage> represents voltage, the unit is the specified unit of the current channel.
<n>: Channel number, n takes value 1, 2.
Return Format
The query returns the lower limit of amplitude of the specified channel in scientific notation.
For Example
:CHANnel1:LIMit:LOWer 2
Set the lower limit of amplitude for CH1 to 2V.
:CHANnel1:LIMit:LOWer?
The query returns 2e+0.
:CHANnel<n>:LIMit:UPPer
Syntax
:CHANnel<n>:LIMit:UPPer {<voltage>}
:CHANnel<n>:LIMit:UPPer?
Description
Set the upper limit of amplitude for the specified channel.
<voltage> represents voltage, the unit is the specified unit of the current channel.
<n>: Channel number, n takes value 1, 2.
Return Format
The query returns the upper limit of amplitude of the specified channel in scientific notation.
For Example
:CHANnel1:LIMit:UPPer 2
Set the upper limit of amplitude for CH1 to 2V.
:CHANnel1:LIMit:UPPer?
The query returns 2e+0.
:CHANnel<n>:AMPLitude:UNIT
Syntax
:CHANnel<n>:AMPLitude:UNIT { VPP|VRMS|DBM}
:CHANnel<n>:AMPLitude:UNIT?
Description
Set the output amplitude unit for the specified channel. If the system is in high/low level mode, this setting
is invalid.
<n>: Channel number, n takes value 1, 2.
Return Format
The query returns the output amplitude unit of the specified channel.
For Example
:CHANnel1:AMPLitude:UNIT VPP
Set the output amplitude unit for CH1 to VPP.
:CHANnel1:AMPLitude:UNIT?
The query returns VPP.