Outside Door Station
When coupled with the optional SmartSense door station, the guest has the
ability to set the room as Do Not Disturb, call for housekeeping or be alerted to
visiting guests with a pleasant doorbell chime. Hotel staff are informed about the
room status or guest’s needs by text information displayed on the door station
LCD or the door station backlight colors.
Figure 14
The connection between the SMART 3000 and the hotel door station is cable
fitted with RJ12 plugs. When fitting the door station, the SMART 3000 DIP Sw8
must be ON. The outside door station will flash all LCD segments if DIP Sw8 is in
the wrong position.
Automatic Day Set Temperature
The SMART 3000 can optionally reset the user setpoint and replace it with an
installer defined setpoint after the SMART 3000 has been OFF for more than six
hours. This will typically happen after one guest has checked out and before the
next guest checks in. Option 40 in the Installer Menu defines this function. Select
OFF or a value between 59 to 86°F (15 to 30°C).