background image

Installation Guide

Program mode allows you to adjust the settings and options of your system.    
Your system has been intelligently designed by installers with years of experience. The system’s default 
settings do not require any program changes in most cases.  However, this system does incorporate a highly 
advanced programming system that includes 3 menus with numerous options and settings that can be easily 
adjusted for custom installations and applications.

User Settings - Page 8

This program menu contains settings that adjust the way the system operates for the user.

Starter Settings - Page 9

This menu controls features and settings associated with remote car starter applications.

Tach Settings - Page 8

This menu allows the programming of the tach signal  and the manual adjustment of that setting. 

Programming Overview

Entering Program Mode

Changing the Programmable Settings

To Enter Program Mode

1)  Make sure ignition is in the off position.
2)  Within three seconds turn the key ON - OFF - ON - OFF - ON. 

Leave in the “ON”

 

 position.

3)  Press and release the Program Button on the antenna 1 time.
4)  Park lights will come on and the horn (optional) will honk to confirm entering program mode.
5)  Select Desired Program Menu by the following:

  

Note

If unit does not enter Program Mode, turn ignition off for 5 seconds and repeat steps 1-4.

  

** The first ignition(Blue wire)

MUST

 be connected to the vehicle’s  first ignition wire. If it is not connected

     it will not be possible to enter the Program Modes.

  Press Button #1   

Lock             User Options

Page 8

  Press Button #3   

Start

   Remote Start Options

Page 9

  Press Button #4        Aux

   Tach Adjustment Menu

Page 8

6) The selected mode will be confirmed by a horn honk (

if connected

)and one park light flash.

7) The program menu may be changed at any time by pressing the transmitter buttons as above, this 

allows the installer to change a setting from one menu, then quickly jump to another menu and 
change another setting without re-entering the Program Mode.

8) Turning off the ignition or 30 seconds of no activity will exit the Program Mode.  This will be confirmed 

by 1 long horn honk and park light flash.

To Select and Change A Program Setting:
1) 

Enter 

Program Mode

.

2) 

Select the desired  

Program Menu.  

(See pages 8 & 9)

3) 

Press  & release the 

Program Button

 the correct number of times to select the desired Program 

Setting(

as listed on pages 8 & 9

).

 

The park lights will flash and the horn (optional) will honk to indicate 

the current setting that is selected.

4)

 Press and hold the Program Button until the parking lights / horn confirm the selected setting.  The 

park lights will flash and the horn (optional)  will honk to indicate the option selected within the setting.

5)

 Turn the ignition key “Off” to exit Program Mode.

NOTE: This procedure is listed in detail below each program setting on pages 8 & 9 of this manual.

PROGRAMMING

STEP 1

 - Within 3 seconds turn the  key ON-OFF-ON-OFF-ON (Leaving Key ON).

STEP 2

 - Press and release the Program  Button.

STEP 3

 - Park Lights will come ON

STEP 4

 - Press the Program Button a second time and hold for 8 seconds until the park lights flash 3 

times and siren chirps 3 times.

System is now re-set to factory defaults.  

NOTE: Reset to defaults does not delete the  transmitters from memory.

SYSTEM RESET

7

Summary of Contents for 1500 SERIES

Page 1: ...mote Vehicle Starter N Version TECH SUPPORT Western Canada 1 800 279 0636 United States 1 866 698 5872 Eastern Canada Bilingual Support 1 800 268 0683 E Mail Tech Support support ultrastarters com Check Our Web Site www ultrastarters com 1500 Automatic and Manual Trans ...

Page 2: ...tton again to check the second code The horn will honk twice to confirm code two Step 5 To Clear Diagnostic Memory While in Diagnostic Mode press and hold the Program Button for five seconds The park lights will flash and the horn optional will honk once NOTE Once diagnostic memory has 4 shutdown events in memory the system will not record any further shutdown events until the system memory has be...

Page 3: ...SWITCH 30amp Output 30amp Output 30amp Input 30amp Input 30amp Output 30amp Output 500ma Output 500ma Output 500ma Output 500ma Output 500ma Output 500ma Output 500ma Output 500ma Output 500ma Output 500ma Output 500ma Output Negative Input Negative Input Negative Input Negative Input A C Input Input Positive Input Positive 15amp Positive Input EXTRA LED OUTPUT OPTIONAL Must be disconnected until ...

Page 4: ... in warranty being VOID and can result in a FIRE The manufacturer is not responsible for any such damages It only takes a few more minutes to do the job RIGHT Mounting The Control Module Never mount the module in the engine compartment Select a location under the dash to install the main module Be certain that the module is securely attached and does not obstruct any serviceable areas Do not force...

Page 5: ...he output on the white wire from the six pin harness To change the output of this wire place the jumper in one of the following positions Note The default setting is second ignition Output on White wire Jumper position Second Starter Position 1 Second Accessory Position 2 Second Ignition Position 3 To change the jumper position you must first remove the access cover as shown in the diagram below T...

Page 6: ...e all the required wire connections and plug in the Unit The park lights should flash twice upon power up 2 Turn the Ignition Key ON Park Lights will turn on 3 Start the vehicle LED s on antenna will come when proper tach signal is detected then after two to ten seconds the park lights will turn off then flash twice to confirm tach learning The system will flash the park lights seven times if not ...

Page 7: ...ptions Page 8 Press Button 3 Start Remote Start Options Page 9 Press Button 4 Aux Tach Adjustment Menu Page 8 6 The selected mode will be confirmed by a horn honk if connected and one park light flash 7 The program menu may be changed at any time by pressing the transmitter buttons as above this allows the installer to change a setting from one menu then quickly jump to another menu and change ano...

Page 8: ... the Program momentarily to move to next program step or repeat to change selection Setting 1 Ignition Auto Lock Setting 2 Horn Honk Settings Setting 3 Door Lock Options PROGRAM MODE TACH SETTINGS Setting 1 Method 2 Low Idle Learn Setting 2 Adjust For Over Crank Setting 3 Adjust For Under Crank PROGRAM MODE USER SETTINGS Step 1 Enter Program Mode Ignition ON OFF ON OFF ON then press the Program bu...

Page 9: ... 1 Flash 10 sec Max time that starter will stay engaged 2 3 Seconds 2 Flashes 3 sec Max time that starter will stay engaged 3 5 seconds 3 Flashes 5 sec Max time that starter will stay engaged 1 Active Starter Kill 1 Flash On when locked Before ignition and 2 seconds after ignition turns off 2 Passive Starter Kill 2 Flashes Same as setting 1 but will arm 60sec after the ignition turns off 3 Bypass ...

Page 10: ... slowly If the vehicle has a dome light delay the vehicle may stay running until the dome light turns off This is normally no longer than 30 seconds Press Once to Lock Doors and arm alarm if equipped Press 2nd Time Hold for Constant Lock Output Press Once to Lock Doors and arm alarm if equipped Press 2nd Time Hold for Constant Lock Output See Owner s Guide for More Detail on Operations Press Once ...

Page 11: ...he park lights will flash five times and the horn optional will honk five times to confirm that the system is in Service Mode 2 While in Service Mode the remote start functions will be disabled and LED s will be ON steady Door locks and trunk release are still operational DEACTIVATING Service Mode 1 While the ignition is ON press and hold the Program Button for five seconds The park lights will fl...

Page 12: ...y or Actuator Green Fused 12V Blue 87 86 85 87a 30 87 86 85 87a 30 Blue Green Lock Un lock Vehicle Lock Unlock Switch To Actuator Fused 12V x x Cut Cut DIAGNOSTICS 87 86 85 87a 30 87 86 85 87a 30 Blue Green Lock Un lock To Vacuum Pump Fused 12V x Cut Ground Negative Type Door Locks Positive Type Door Locks 5 Wire Reverse Polarity Type Door Locks Vacuum Type Door Locks RELAY DIAGRAMS 12 ...