Installation Guide
WIRING CONNECTORS
Yellow
Starter
30amp output
12volts during crank only.
Green
Heater
30amp output
12volts in accessory off during start.
Red
12 power
30amp input
Constant 12volt power at ignition harness.
Red
12 power
30amp input
Constant 12volt power at ignition harness.
Blue
Ignition 1
30amp output
12volts in ignition and start positions.
White
Selectable
30amp output
Selectable Output. See bottom of page.
6 Pin Power Connector
14 Pin Connector
Green
Door Lock
Door Lock Output -
Programmable - Menu 1 Setting 3.
Red
12 Volts
Low Current output for voltage inverter
Blue
Door Unlock
Door Unlock Output -
Programmable - Menu 1 Setting 3.
Pink
2nd Unlock
2nd Unlock Output -
Programmable - Menu 1 Setting 3.
4 Pin Connector Red
2 Pin Connector White
5
Yellow
(-) Park Lights
Negative output for negative park light system.
Black
(-) Horn
Negative output for horn activation.
Jumper Selections
Position One
Second Starter
Output On the White Wire From The 6-Pin Connector.
Position Two
Second Accessory
Output On The White Wire From The 6-Pin Connector.
Position Three
Second Ignition*
Output On The White Wire From The 6-Pin Connector.
* The Default Setting For The System Is Second Ignition Output.
1 2
3
The jumpers control the output on the white wire from the six pin harness. To change the output of this
wire, place the jumper in one of the following positions
Note: The default setting is second ignition.
Output on White wire Jumper position
Second Starter Position 1
Second Accessory Position 2
Second Ignition Position 3
To change the jumper position you must first remove the access cover as shown in the diagram below.
The access cover will slide out of its position when pushed outwards from the center of the module.
Push
Yellow
Re-Arm
0.75sec Pulse With Lock And On Shutdown.
Orange
Starter Kill
Negative While Locked. Starter kill output. - **
Starter Program Mode.
Brown
Disarm
0.75sec Pulse With Unlock And Before Start.
Red/White
3rd CH
Trunk Release - Active When The Unlock Button Is Held For 3seconds.
Wht/Violet
(-) Out
Negative Output While Remote Started.
Green
(-) Door
Negative Door Trigger Input -
Manual Trans And Alarm Units Only.
Green/White
Hood Pin
Negative Hood Pin Input -
MUST BE CONNECTED!!
Purple
(+) Door
Positive Door Trigger Input -
Manual Trans And Alarm Units Only.
Pink
Brake
Positive Brake Input -
MUST BE CONNECTED!!
Black
Ground
System Ground Input -
MUST BE CONNECTED!!
Blue/White
Tach
Tach Signal Input
-
MUST BE CONNECTED!!
Blue
Glow Plug
Negative Glow Plug Input -
DIESEL ENGINE ONLY. **See Starter Program Mode
White
Park Lights Positive Park light Output -
10 Amp Max.
Black/White
Park Brake Negative Park Brake Input -
Manual Transmission Models Only.