Installation, Operation and Maintenance Manual
UFO
35
uk.ufosecurity.com
ERROR CODES
When the machine is in error, the white LED will be flashing. To determine the
type of error, count the number of consecutive flashes between the pauses:
- Off: no error;
- 1: Error reading internal memory;
- 2: Generic internal error;
- 3: Internal error, machine status not recognised;
- 4: Internal error, machine state switched to an unacknowledged state;
- 5: Thermocouple not recognised, reading on keypad ‘nan’;
- 6: Boiler overtemperature, temperature greater than 500 °C detected;
- 7: Flow meter error, fault in the flow meter or liquid does not flow;
- 8: Temperature error, boiler does not come up to temperature;
- 9: Command refused. An unmanageable command has been given.
- 10: Firing not started
Errors can be reset either from the app or with the multifunction button.
MULTI FUCTION BUTTON
For the multi-function button to be counted, the
machine must be in the DISARM state. While
holding it down, the Red, Blue and White LEDs
will start flashing at 1 second intervals. Counting
the flashes, the button is released according to
the number of flashes involved. Each number of
flashes corresponds to a function:
- 1 flash: Liquid reset, the consumed liquid count
is reset;
- 2 flashes: Error reset, the errors present are
cleared;
- 3 flashes: UFO restart, the board is restarted;
- 4 flashes: Web Server mode, used to configure
the fogger’s Wi-Fi settings.
- 5 flashes: Bag change mode. See Bag Change
Procedure section for more information.
Summary of Contents for Basic L
Page 2: ......
Page 4: ...01 Declaration of conformity p 5 Manufacter data p 7 Presentation of the Manual p 8...
Page 19: ......
Page 47: ...Installation Operation and Maintenance Manual UFO 47 uk ufosecurity com PIN ILLUSTRATION...
Page 49: ......
Page 50: ...04 Maintenance p 50 Decommissioning p 52...
Page 54: ...Installation Operation and Maintenance Manual UFO uk ufosecurity com 54...