55
– make sure that ignition is started up, key code is recognized
(the immobilizer turning-on signal device
is OFF);
– 10 seconds after starting up, shut ignition, turning the key
into the 0 position (Fig. 3.10);
– for 10 s start up the ignition using another registered key,
make sure that the ignition is started up, the key is recognized;
– 10 s after starting up, shut ignition. The immobilizer turning-
on signal device
starts blinking, the system is ON;
– for 20 s (signal device blinking time) press the accelerator
pedal. When the system recognizes full pressing of the accelerator
pedal, the immobilizer turning-on signal device
is OFF;
– keep the accelerator pedal pressed for 60 s. After that the
immobilizer turning-on signal device starts blinking;
– for 20 s (signal device blinking time) start up the ignition using
the key to be registered (not the first and not the second registered
key). The immobilizer turning-on signal device is continuously lit.
Release the accelerator pedal. Key registration is completed if in
2 s the signal device goes out. If the signal device starts blinking,
the key registration is considered incomplete and the registration
process is interrupted;
– 10 s after starting up the ignition, shut ignition and remove the
key from the ignition starter switch. For registration of additional
keys start the ignition up with the key to be registered within 20 s
return to the previous operation;
– to finish the key registration, start ignition using the second (from
the start of the procedure) registered key. The immobilizer turning-on
signal device continues blinking for 2 s and then switches OFF;
– 10 s after starting up the ignition, shut ignition and remove
the key from the ignition starter switch;
– for 20 s (signal device blinking time), start up the ignition
using the first (from the start of the procedure) registered key. The
signal device switches OFF. After that, the system deletes all key
codes registered during the previous teaching session and registers
all keys used in the current registration procedure (the first, the
second registered keys and additional keys). Key registration is
completed if the signal device switches ON and goes out in 2 s.