Appendix C – Table of MFC710 frequency converter's parameters
Parameter / Name
Function
Available options / measurement unit
Factory
setting
Change
during
operation
5.51 Seq Nxt
Source of “next state”
signal
PCH.000 Sw.Off (disabled) ... PCH.511
PCH.000
Sw.Off
YES
5.52 Seq Prv
Source of “previous state”
signal
PCH.000 Sw.Off (disabled) ... PCH.511
PCH.000
Sw.Off
YES
5.53 Seq Clr
Source of “sequencer
restart” signal
PCH.000 Sw.Off (disabled) ... PCH.511
PCH.000
Sw.Off
YES
5.54 Seq Set
Source of “sequencer
setting” signal
PCH.000 Sw.Off (disabled) ... PCH.511
PCH.000
Sw.Off
YES
5.55 Seq SV
Sequence to which
sequencer block will be set
after “Seq Set” signal
PCH.000 Sw.Off (disabled) ... PCH.511
(value 0 = sequencer 0)
PCH.000
Sw.Off
YES
5.60 En. Mux1
Signal of switching on
MUX1 PLC block
PCH.000 Sw.Off (disabled) ... PCH.511
PCH.000 = MUX1 disabled
PCH.000
Sw.Off
YES
5.61 nu
Service parameter
5.62 Mux1 DV
Value of MUX1 output
(PCH.313) when MUX1 is
disabled (par. 5.60)
-32000 ... 32000
0
YES
5.63 Mux1 Sel
Source of MUX1 input
selection
PCH.000 ... PCH.511
PCH.000
YES
5.64 Mux1 In.1
Value of input 1 MUX1
PCH.000 ... PCH.511
PCH.000 (=0) YES
5.65 Mux1 In.2
Value of input 2 MUX1
PCH.000 ... PCH.511
PCH.000 (=0) YES
5.66 Mux1 In.3
Value of input 3 MUX1
PCH.000 ... PCH.511
PCH.000 (=0) YES
5.67 Mux1 In.4
Value of input 4 MUX1
PCH.000 ... PCH.511
PCH.000 (=0) YES
5.68 Mux1 In.5
Value of input 5 MUX1
PCH.000 ... PCH.511
PCH.000 (=0) YES
5.69 Mux1 In.6
Value of input 6 MUX1
PCH.000 ... PCH.511
PCH.000 (=0) YES
5.70 Mux1 In.7
Value of input 7 MUX1
PCH.000 ... PCH.511
PCH.000 (=0) YES
5.71 Mux1 In.8
Value of input 8 MUX1
PCH.000 ... PCH.511
PCH.000 (=0) YES
5.80 En. Mux2
Signal of switching on
MUX1 PLC block
PCH.000 ... PCH.511
PCH.000 = MUX2 disabled
PCH.000
Sw.Off
YES
5.81 nu
Service parameter
5.82 Mux2 DV
Value of MUX2 output
(PCH.314) when MUX2 is
disabled (par. 5.80)
-32000 ... 32000
0
YES
5.83 Mux2 Sel
Source of MUX2 input
selection
PCH.000 ... PCH.511
PCH.000
YES
5.84 Mux2 In.1
Value of input 1 MUX2
PCH.000 ... PCH.511
PCH.000 (=0) YES
5.85 Mux2 In.2
Value of input 2 MUX2
PCH.000 ... PCH.511
PCH.000 (=0) YES
5.86 Mux2 In.3
Value of input 3 MUX2
PCH.000 ... PCH.511
PCH.000 (=0) YES
5.87 Mux2 In.4
Value of input 4 MUX2
PCH.000 ... PCH.511
PCH.000 (=0) YES
5.88 Mux2 In.5
Value of input 5 MUX2
PCH.000 ... PCH.511
PCH.000 (=0) YES
5.89 Mux2 In.6
Value of input 6 MUX2
PCH.000 ... PCH.511
PCH.000 (=0) YES
5.90 Mux2 In.7
Value of input 7 MUX2
PCH.000 ... PCH.511
PCH.000 (=0) YES
5.91 Mux2 In.8
Value of input 8 MUX2
PCH.000 ... PCH.511
PCH.000 (=0) YES
5.100 nu
Service parameter
5.101 CSU In.
CSU Input (X)
PCH.000 (Sw.Off) ... PCH.511
PCH.000
YES
5.102 CSU X1
Point 1, value X
-32000 ... 32000 (see CSU description)
0
YES
5.103 CSU Y1
Point 1, value Y
-32000 ... 32000
0
YES
5.104 CSU X2
Point 2, value X
-32000 ... 32000
0
YES
5.105 CSU Y2
Point 2, value Y
-32000 ... 32000
0
YES
5.106 CSU X3
Point 3, value X
-32000 ... 32000
0
YES
5.107 CSU Y3
Point 3, value Y
-32000 ... 32000
0
YES
5.108 CSU X4
Point 4, value X
-32000 ... 32000
0
YES
5.109 CSU Y4
Point 4, value Y
-32000 ... 32000
0
YES
5.110 CSU X5
Point 5, value X
-32000 ... 32000
0
YES
5.111 CSU Y5
Point 5, value Y
-32000 ... 32000
0
YES
94
Frequency converter MFC710 type. TWERD Power Electronics