Front panel lock
0FC
0 = unlocked, 1 = locked
10.4
Examples
Each example shows the packet sent to the unit and its response. When a byte is
not required to be sent it is indicated by a ‘- ‘in the table below (since a Read is 6
bytes shorter than a Write). Each character shown below is sent as a ASCII
character so F0400 is sent as ‘F’ ‘0’ ‘4’ ‘0’ ‘0’.
Packet sent
Packet returned
SOP CMD CHA WIN OUT FUN PAY
CS EOP
SOP CMD CHA WIN OUT FUN PAY
CS EOP
Set output 1 window B Source to RGB2
F
04
00
42
00
82
000011
D9 CR
F
44
00
42
00
82
000011 19 CR
Set output 1 window A to Enable advanced aspect
control
Note checksum is ?? for debugging
F
04
00
41
01
02
000001
??
CR
F
44
00
42
01
02
000001 8A CR
Set 1A Shrink to 110 – invalid max for shrink is 100
F
04
00
41
00
87
00006E ??
CR
F
44
00
41
00
87
000064 70 CR
Read 1C Zoom level – invalid as window C does not exist
F
84
00
43
00
86
-
??
CR
F
04
00
43
00
86
000000 CD CR
Read 1B Zoom level
Zoom = 100
F
84
00
42
00
86
-
??
CR
F
44
00
42
00
86
000064 70 CR
Set baud to 9600
Reply is at 9600 baud
F
04
00
42
00
AB
000000
F0
CR
F
44
00
42
00
AB
000000 30 CR
Set 1A Zoom = 300
F
04
00
42
00
86
00012C F7
CR
F
44
00
42
00
86
00012C 37 CR
Set 1A Shrink to 50
F
04
00
42
00
87
000032
FE CR
F
44
00
42
00
87
000032 3E CR
Set 1A Shrink H Posn to 0
F
04
00
42
00
DA
000000
1F
CR
F
44
00
42
00
DA
000000 5F CR
Set 1A Shrink V Posn to 100
F
04
00
42
00
DB
000064
84
CR
F
44
00
42
00
DB
000064 C4 CR
10.5
Reading and writing macros
Depending on the unit connected there can be up to 7 macros stored in the unit.
These macros can be programmed to perform a specific task, for example enable
PIP mode, Position pip window at H=0, V=0, Zoom in to 120%.
The WIN and OUT bytes are not used for macro reading or writing and should be set
to WIN=1A and OUT = 0