All stored settings except resolutions are lost when the unit is
reset. A Firmware update is the only way to perform a complete
factory reset (including resolution data).
5.3.3
Switching units between different resolutions (NTSC, PAL and Default)
Down converters will default to outputting NTSC after a Factory Reset, whilst Video
Scalers will default to outputting XGA (1024x768 @ 60Hz). Should your display or
output source not support the default resolution, or if you wish to have quick access
to an alternate resolution, the following methods below can be used. When you are
happy with the output resolution selected, press and hold the multi-directional switch
in to store the current settings.
Please note that these changes will have no immediate effect if LOCK or MIX
buttons are illuminated, as this means that the output resolution is locked to the Lock
source.
5.3.4
Forcing NTSC output resolution
Press and hold the RGB(1) button and FREEZE button together, then release.
5.3.5
Forcing PAL output resolution
Press and hold the RGB(1) button and ZOOM button together, then release.
5.3.6
Forcing default output resolution
Press and hold the RGB(1) button and PAN button together, then release. The
default output resolution depends on the type of unit you have – see above.