Infrared Camera – Operating Manual

 

B -

 

14

Saturation colour 

When activated, the width of the image with the high-
est temperature is coloured green.

Isotherm width 

Sets the width of isothermal intervals. The width can be 
adjusted  from  0.1  to  the  upper  limit  of  the  maximum 
temperature measurement range under this condition. 

Isotherm colour

Sets  the  colour  of  the  isotherm  interval  to  either 
green, black opr white or to transparent.

Isotherm type

Isotherm 

Type

Dual 

Above

Shows all temperatures within the set 

isotherm intervals in one colour and in 

addition all areas which are warmer than 
the upper interval threshold in a different 

colour.

Dual 

Below

Shows all temperatures within the set iso-

therm intervals in one colour and in addition 

all areas which are colder than the lower 

interval threshold in a different colour.

Above

Shows the isotherm interval and all areas 
which are warmer than the upper interval 

threshold in the same colour.

Below

Shows the isotherm interval and all areas 

which are colder than the upper interval 

threshold in the same colour.

Interval

Shows the set isotherm interval in one 

colour. The rest of the image is displayed 

in IR pseudo colours.

Isotherm alarm

The alarm threshold value can be set between 1 and 100 
and describes the proportion (in %) between 1/100 and 
100/100 of the area of the LCD, eg. the isotherm range 
is between 35°C and 40°C and the Iso-Alarm is 100. In 
this case the alarm is triggered when 100% of the area 
shown in the LCD is between 35°C and 40°C and the 
whole area of the LCD is correspondingly “isotherm”- co-
loured. If the alarm threshold value is set, for example, at 
40, the alarm will be triggered when 40% of the area of 
the LCD is “isotherm”- coloured.

Spot analysis

The following subject matter briefly explains how to 
set the analysis tools on the thermal image.
1. Press the MENU/ENTER key.

2.  Press  the  up 

or 

    down 

t

  key  on  the 

    omni selector to get to  
    the  menu  item  [Analy- 
    sis].

3. Setting the spot analysis
    • Press  the  up 

or 

      down 

arrow  on 

      the  omni  selector  
      to  select  a  spot,  
      then press MENU/ 
      ENTER  key.  One  or  
      more  crosshairs  will  
       appear on the screen.
    • Spot 5 will automatically track the highest or  
      lowest spot on the screen.
4. Moving the analysis spot
    • Start from Step 1 to  
      set or select a spot  
      analysis. 
    • Press  the  up 

s

      down 

t

,  left 

      right   arrow on the 
      omni  selector  to  
      move  the  activated  
      spot. 
      Temperature  value  
      of  the  current  spot  
      will be modified
5. Removing  the  meas- 
    uring spots.

   

• Start  with  Step  1 

      and select the meas- 
      uring spot you wish to remove.

   

• Press C to remove the measuring spot.

   

tracking the measuring spot

   

Set Spot 5 or Spot 10 so that it tracks the highest/

    lowest point on the display.

Measured 

Temperature

Summary of Contents for POWERSHRED

Page 1: ...TROTEC GmbH Co KG Grebbener Stra e 7 D 52525 Heinsberg Tel 49 2452 962 400 Fax 49 2452 962 200 www trotec de E Mail info trotec de TRT EC060 HS 003 GB EC Series EN Infrared Camera Operating Manual B 1...

Page 2: ...n B 17 06 Recording and Deleting B 17 Opening Images B 17 Selecting Images B 17 Selecting the Name of the Current Folder B 18 Voice Annotations B 18 Deleting Images B 18 07 Reading Out Images B 19 Rea...

Page 3: ...turn off the power of the camera remove thebattery from the camera or unplug the power cord from the power outlet Check to see that no more smoke or fumes are coming out of the camera Stop operating i...

Page 4: ...en the IR camera is not in use to avoid fires and other hazards Non stop operation use over a long period of time may cause the device to overheat and deform resul ting in fire Do not use the battery...

Page 5: ...s Locking Ring Trigger Multi functional Docking Station Rear View KeyPad LCD Monitor USB Terminal Video Output Terminal Battery SD Card Cover Controls Multi function Docking Station Auto Adjust Key Po...

Page 6: ...le charger to charge your battery When the charging cycle has been completed discon nect the charger from the mains supply and remove the battery Your camera is equipped with a lithium ion battery whi...

Page 7: ...the operating indicator The operating indicator shows which operating status the camera is in Menu shows the menu mode Zero shows the non menu No analysis tools is selected 1 4 shows the current anal...

Page 8: ...settings This menu item can be used to change the style of the menu system 1 Check that the IR camera is in zero mode 2 Press the MENU EN TER key then press the up s or down t arrow on the omni select...

Page 9: ...ng target is in the centre of the display The LCD monitor will switch itself off when closed Selecting Menus and Settings You can select the settings by pressing the MENU ENTER key 1 Press the MENU EN...

Page 10: ...ill not be deleted when you reset the menu and button operation settings to default 05 MEASURING Manual Focusing 1 Check to ensure that the IR camera is in null mode 2 Point the camera at the object y...

Page 11: ...y and the arrow keys in order to adjust the thermal image so that it covers the visual image Moving the DuoVision area Move upwards C UPs Move downwards C DOWNt Move left C LEFT Move right C RIGHT WAR...

Page 12: ...NU ENTER key to save the changes or press the C key to close the window without saving any new settings Information regarding image settings Auto adjust Sets the function of the A key There are three...

Page 13: ...close the window when this step is completed Freezing Activating an Image You can freeze or activate a thermal image by pres sing the S key on the selector 1 Check that the IR came ra is in zero mode...

Page 14: ...down t arrow on the omni selector to select the menu item Analysis then press the MENU ENTER key 3 Press the up s and down t arrow on the omni selector to select Setup then press the MENU ENTER key 4...

Page 15: ...en 1 and 100 and describes the proportion in between 1 100 and 100 100 of the area of the LCD eg the isotherm range is between 35 C and 40 C and the Iso Alarm is 100 In this case the alarm is triggere...

Page 16: ...andAverage temperature of the selected area Press the left or right key to select between the Max Min or Average temperature of the selected area When Area 5 is selected the Max Min and Ave rage temp...

Page 17: ...therm range by changing the lower isotherm level IL The letters IL and IH appear in the bottom right hand corner IH is the upper threshold and IL the lower threshold of the isotherm range Removing Ana...

Page 18: ...down arrow on the omni selec tor to select menu item Others and then press the MENU ENTER key Trigger Information Save Press the trigger to save an image Laser on Press the trigger to activate the la...

Page 19: ...luetooth headset optional and open an image 2 Press the MENU ENTER key then press the up or down arrow on the omni selector to select the File menu and confirm 3 Press the s up or down t arrow on the...

Page 20: ...ture when the camera is used in continuous operation Ple ase ensure that you only use original Trotec mains adapters to avoid any damage from occurring to your camera Connecting to a monitor The camer...

Page 21: ...stall programs 1 After a few moments the following dia logue will appear 2 Select No notthistime then click Next 3 Select Installfromalist or location Advanced then click Next 4 Select Include this lo...

Page 22: ...etooth headset first Press and hold the power button A for about 5 seconds The power indicator starts to blink in red and then blue The headset is in pairing mode after 2 seconds ThebLEDblinksmoreslow...

Page 23: ...l Save the images onto your computer and delete them from the SD card Internal memory not formatted correctly Format the memory in FAT32 format Battery power exhausted Battery capacity reduced because...

Page 24: ...00 1400 0 29 Melting mild steel 1600 1800 0 28 Liquid steel 1500 1650 0 42 0 53 Pure lead 1515 1680 0 42 0 45 Silver Polished Silver 100 0 05 Material Temperature C Emissivity approx Nickel Nickel chr...

Page 25: ...na 25 600 0 55 Mild alumina 25 600 0 10 0 20 Strong alumina 25 600 0 30 0 40 Copper Cuprous oxide 800 1100 0 16 0 13 Material Temperature C Emissivity approx Non metallic materials Mica 0 94 0 95 Flam...

Page 26: ...res Image freeze Live or freeze File function Removable SD card up to 2 GB Measurement Temperature range 20 C 250 C Accuracy 2 C or 2 Analysis Functions Spots 2 10 spots Temperature tracking Tracks th...

Page 27: ...or 8 11V DC supply to charge the battery inside BWT 2 5 hours Environmental specification Operational temperature 15 C 50 C Storage temperature 40 C 70 C Relative humidity 10 95 Interfaces Mechanism w...

Page 28: ...TROTEC GmbH Co KG Grebbener Stra e 7 D 52525 Heinsberg Tel 49 2452 962 400 Fax 49 2452 962 200 www trotec de E mail info trotec de...

Reviews: