background image

19

6

Parts Included in the TrojanUVMax™ System

Power supply (90-265Vac)

Models D, E, F, Pro7 & Pro15

Power supply

120Vac or 230Vac

for Model A

One Stainless
Steel Reactor

One Lamp / Sleeve

Assembly

One Power Cord

120Vac or 230Vac

(only with 90-265 Vac power supply)

One UV Sensor

(only on models with this option)

One of the above power supplies

Reactor Clamp(s)

(material of clamps
depends on model)

One warranty card

One owner’s manual

One-Year Limited Warranty
for Lamps, Sleeves, and 
UV sensors

Trojan warrants lamps, sleeves, and UV 
sensors to be free from defects in 
material and workmanship for a period
of one (1) year from the date of 
purchase. During this time, Trojan will
repair or replace, at its option, any
defective parts covered by the warranty.

The warranty period for lamps and
sleeves may be verified using date codes
in addition to purchase receipts and
Trojan’s database of registered owners.
Trojan will let you know whether the
defective item needs to be returned to a
Trojan dealer for failure analysis.
Replacement lamps and sleeves provided
under warranty will be sent to your
Trojan dealer.

If the UV sensor experiences a problem
that Trojan confirms is covered by 
warranty, please return the sensor to a
Trojan dealer, who will return it to
Trojan. Trojan will either repair or
replace the sensor and send the sensor
to your dealer.

This warranty on lamps, sleeves, and 
sensors does not include shipping and 
handling charges, which will be collected
from you by the dealer.

Parts replaced under this one-year 
warranty will be covered under warranty
to the end of the original one-year 
warranty period.

This warranty is also subject to the 
conditions and limitations outlined under
the heading “General Conditions and
Limitations”.

Warranty for Replacement 
Lamps and Parts

Trojan warrants replacement lamps, 
purchased for annual routine 
maintenance, and other parts purchased
to repair components no longer covered
by original warranty, to be free from
defects in material and workmanship for
a period of three (3) months from the
date of purchase. During this time,
Trojan will repair or replace, at its
option, a defective replacement lamp or
part free of charge except for shipping
and handling charges.

The warranty period on replacement
lamps and parts will be verified using
date codes or purchase receipts or both.
Trojan will let you know whether the
defective item needs to be returned to a
Trojan dealer for failure analysis.
Replacement lamps and parts provided
under warranty will be sent to your
Trojan dealer.

General Conditions and
Limitations

None of the above warranties cover 
damage caused by improper use or
maintenance, accidents, acts of God, or
minor scratches or imperfections that do
not materially impair the operation of the
product. The warranties also do not
cover products that are not installed as

outlined in the applicable 
Owner’s Manual.

The limited warranties described
above are the only warranties 
applicable to the Trojan products 
listed in the “Specific Warranty
Coverage” section. These limited 
warranties outline the exclusive 
remedy for all claims based on a 
failure of or defect in any of these
products, whether the claim is based
on contract, tort (including 
negligence), strict liability, or 
otherwise. These warranties are in
lieu of all other warranties whether
written, oral, implied, or statutory.
Without limitation, no warranty of
merchantability or of fitness for a 
particular purpose shall apply to any
of these products.

Trojan does not assume any liability
for personal injury or property 
damage caused by the use or misuse
of any of the above products. Trojan
shall not in any event be liable for
special, incidental, indirect, or 
consequential damages. Trojan’s
liability shall, in all instances, be 
limited to repair or replacement of
the defective product or part and this
liability will terminate upon expiration
of the applicable warranty period.

Part numbers:

O-Ring

Sleeve Bolt

O-Ring

Quartz Sleeve

Lamp

Power supply 

(90-140Vac or 190-260Vac)

for Models B & C

A

650389 650390

B

650356 650357

C

650356 650357

602725

602730

602665

002045

602726

602731

602665

002045

602727

602732

602665

002045

602764

602765

602766

Model

Power Supply*

Sleeve
Bolt

Quartz
Sleeve

O-Ring

Lamp

254nm 185nm

120V

  230V

602662

602636  602637

D

602636  602637

E

602662

 602636  

602637

F

602662

602636  602637

Pro7

N/A

602636  602637

Pro15

N/A

602724
602724
602724
602724
602724

UV

Sensor

Kit

602661

602727

602732

602665

002045

650505

602661

602728

602733

602665

002045

650505

602661

602729

602766
602767
602768

602734

602665

002045

650505

602661

602728

602733

602665

002045

650505

602661

602729

N/A
N/A

602734

602665

002045

650505

with

sensor

w/o

sensor

Model

Lamp Harness

Power Cord

Remote

Options

Cord

Sleeve

Bolt

Quartz

Sleeve

O-Ring

Lamp

254nm 185nm

Power Supply*

with

sensor

w/o

sensor

650507
650507
650507
650507
650507

650506
650506

650506

N/A
N/A

120V

230V

* includes lamp harness and power cord

Power Cord

Remote Options
Cord (optional)

Lamp Harness

UV Sensor (optional)

Power Cord

Power Cord

Lamp Harness

Lamp Harness

Summary of Contents for Trojan UV Max

Page 1: ...n _______________________________________________________________________________________________________________________________ For service and lamp orders call your installer at ___________________...

Page 2: ...tandard 53 Drinking Water Treatment Units Health Effects shall be installed upstream of the system NSF Standard 55 defines waste water to include human and or animal body waste toilet paper and any ot...

Page 3: ...ensor has reduced detected UV intensity Coating on the UV sensor has reduced detected UV intensity Coating must be removed for correct operation Follow cleaning procedures in manual Coating must be re...

Page 4: ...amp harness before removing lamp from reactor 10 If the UV system malfunctions or fails which is indicated by the system s audible alarm and red LED light water must be boiled prior to consumption unt...

Page 5: ...lways disconnect the extension cord from the receptacle before disconnecting this system from the extension cord Never yank cord to pull plug from outlet Always grasp the plug and pull to disconnect T...

Page 6: ...ailure analysis Replacement lamps and parts provided under warranty will be sent to your Trojan dealer General Conditions and Limitations None of the above warranties cover damage caused by improper u...

Page 7: ...d Electrical Components Trojan warrants the structural hardware and electrical components to be free from defects in material and workman ship for a period of five 5 years from the date of purchase Du...

Page 8: ...nstallation or Replacement of UV Lamp Sleeve section to remove the lamp sleeve p 12 2 Clean the sleeve by using a commercial grade remover such as Lime A WayTM or CLRTM on a high quality lint free cot...

Page 9: ...n the attached cord may shorten the UV sensor s life Installation 1 Always disconnect the power to the power supply before installing servicing or maintaining the UV system To avoid injury avoid direc...

Page 10: ...0 or 60Hz Visual Alarm During normal operation the LED light will be green The LED is always on while the lamp is on The LED will turn amber after 11 months of operation or on the Plus models if the s...

Page 11: ...Sensor The UV sensor measures the amount of UV light reaching it allowing the system to monitor whether the intensity is above the minimum required for proper dis infection The sensor is factory calib...

Page 12: ...screw driver shaft into one of the slots in the top of the lamp end Figure 6 Lamp Installation 1 Ensure O ring and seating area are clean prior to assembly Place the O rings and the sleeve bolt on the...