background image

4

21

WARNING – 
To guard against injury, basic safety precautions
should be observed, including the following:

1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
2. DANGER – To avoid possible electric shock, special care should be taken since water is employed in the

use of this system. Do not attempt repairs yourself. No user serviceable parts. Return the system to an
authorized service facility for service or discard the system.

3. Do not operate the system if it has a damaged cord or plug, or if it is malfunctioning or if it has been

dropped or damaged in any manner.

4. Always unplug the system from an outlet before servicing or cleaning. Never yank cord to pull plug from 

outlet. Always grasp the plug and pull to disconnect.

5. Do not use the system for other than intended use. The use of attachments or accessories not recommended

or sold by Trojan Technologies may cause an unsafe condition and/or reduce disinfection performance.

6. CAUTION – To prevent risk of electrical shock, connect this system only to a properly grounded, grounding-

type power supply receptacle that is protected by a Ground Fault Circuit Interrupter (GFCI). Inspect 
performance of GFCI as per manufacturer’s suggested maintenance schedule.

7. Visually inspect this system prior to installation. If the quartz sleeve or lamp is broken, cracked or damaged 

in any way, do not use. Contact Trojan Technologies Client Services for replacement parts.

8. WARNING – To reduce the risk of electrocution, keep all connections dry and off the ground. Do not touch

plug with wet hands.

9. The light emitted by the lamp will cause serious eye damage and burn unprotected skin. Never look directly

at the lamp when it is operating.  Do not plug unit into an electrical outlet without properly securing the
lamp/sleeve into the reaction chamber. Disconnect lamp harness before removing lamp from reactor. 

10. If the UV system malfunctions or fails (which is indicated by the system’s audible alarm and red LED light)

water must be boiled prior to consumption until the UV system is operational and the water lines have been
shocked.

11. Always shut off water flow and release water pressure before cleaning or maintaining unit.
12. Intended for indoor use only. Power supply must not be exposed to weather elements.  In seasonal 

applications, reactor must be drained to prevent freezing.

13. Installation of this system must be in accordance with Provincial/State and local laws and regulations.
14. SAVE THESE INSTRUCTIONS.

Indication of lamp failure through 
audio/visual alarms.

Inspect lamp harness and reconnect.
Ensure harness SNAPS into place.

Elapsed Time Meter changes to

F0

 or 

F1

Replace lamp within the next month

Restart

Elapsed Time Meter changes to
read 

C0

Restart

Continuity across pins on lamp  
OK and alarm still sounds

Power supply failure

Replace power supply

Lamp not operating due to improper
connection of lamp harness

Lamp has operated for 11 months

           

SITUATION 

              POSSIBLE CAUSE 

    POSSIBLE SOLUTION

Indicator light glows amber and 
Elapsed Time Meter reads 11

Ballast improperly driving lamp

LED is malfunctioning

Elapsed Time Meter indicates the 
month is >12 and is flashing.  
Indicator light glows red and is 
flashing. Alarm is sounding.

Indicator light continues to glow 
red and alarm continues to sound
after lamp/sleeve replacement

Indicator light glows red and alarm
is sounding

Have reached the end of lamp life

Lamp not operating due to improper
connection of lamp harness

Lamp not operating due to improper
connection of lamp harness

Lamp not operating due to general
or shipping damage

Replace lamp and reset elapsed time 
meter

Inspect lamp harness and reconnect.
Ensure harness SNAPS into place.

Check for continuity across pins of lamp.
Replace lamp if reading is open.

Inspect lamp harness and reconnect.
Ensure harness SNAPS into place.

Summary of Contents for Trojan UV Max

Page 1: ...n _______________________________________________________________________________________________________________________________ For service and lamp orders call your installer at ___________________...

Page 2: ...tandard 53 Drinking Water Treatment Units Health Effects shall be installed upstream of the system NSF Standard 55 defines waste water to include human and or animal body waste toilet paper and any ot...

Page 3: ...ensor has reduced detected UV intensity Coating on the UV sensor has reduced detected UV intensity Coating must be removed for correct operation Follow cleaning procedures in manual Coating must be re...

Page 4: ...amp harness before removing lamp from reactor 10 If the UV system malfunctions or fails which is indicated by the system s audible alarm and red LED light water must be boiled prior to consumption unt...

Page 5: ...lways disconnect the extension cord from the receptacle before disconnecting this system from the extension cord Never yank cord to pull plug from outlet Always grasp the plug and pull to disconnect T...

Page 6: ...ailure analysis Replacement lamps and parts provided under warranty will be sent to your Trojan dealer General Conditions and Limitations None of the above warranties cover damage caused by improper u...

Page 7: ...d Electrical Components Trojan warrants the structural hardware and electrical components to be free from defects in material and workman ship for a period of five 5 years from the date of purchase Du...

Page 8: ...nstallation or Replacement of UV Lamp Sleeve section to remove the lamp sleeve p 12 2 Clean the sleeve by using a commercial grade remover such as Lime A WayTM or CLRTM on a high quality lint free cot...

Page 9: ...n the attached cord may shorten the UV sensor s life Installation 1 Always disconnect the power to the power supply before installing servicing or maintaining the UV system To avoid injury avoid direc...

Page 10: ...0 or 60Hz Visual Alarm During normal operation the LED light will be green The LED is always on while the lamp is on The LED will turn amber after 11 months of operation or on the Plus models if the s...

Page 11: ...Sensor The UV sensor measures the amount of UV light reaching it allowing the system to monitor whether the intensity is above the minimum required for proper dis infection The sensor is factory calib...

Page 12: ...screw driver shaft into one of the slots in the top of the lamp end Figure 6 Lamp Installation 1 Ensure O ring and seating area are clean prior to assembly Place the O rings and the sleeve bolt on the...