SERVICE 
AND MAINTENANCE

There are two regular maintenance 
requirements common to all UV 
systems: lamp replacement and
sleeve cleaning.

Lamp Replacement

The lamp’s UV intensity decreases
over time. You can safely use your
lamp for 12 months, after which it
must be replaced. For instance, if you
use your system for 12 continuous
months, you must replace your lamp
at the end of this period. If you use
the system only six months each year,
you would need to change your lamp
at the end of the second six-month
period.

Sleeve Cleaning

Minerals in the water will 
eventually coat the quartz sleeve 
that protects the lamp. This 
coating must be cleaned off 
periodically because it reduces the
UV intensity reaching the water. Once
a month, check the sleeve and clean
it if you can see a mineral coating
starting to form. You can use a soft
cloth with acid solutions or cleaners
such as Lime-A-Way

TM

, CLR

TM

or

regular vinegar to clean the sleeve.

INSTALLATION OR
REPLACEMENT OF UV
LAMP/SLEEVE

Lamp Removal

1. Shut off water supply to (upstream

of) the UV system.

2. Open a tap downstream of the UV

unit to release pressure, then
close this tap.

3. Unplug the power supply.

4. Let the lamp cool for 5 minutes.

5. Remove the lamp harness:

Release the safety clips by gently
applying outward pressure on the
finger tabs and push off the grey
plastic cover (see Figure 1 on
p.15) or gently squeeze the sides
of the cover adjacent to the snap
fingers (Figure 2). When the cover
is removed you can pull the lamp
plug off the lamp end (Figure 3).

Caution:

Do not pull on the lamp

harness cord to remove the plug.

6. Unscrew the lamp/sleeve assembly

and carefully remove it from the
reactor (Figure 4). Handle
lamp/sleeve at ends only. If
required, a wrench can be placed 
on the flat sides of the sleeve bolt, 
just below the snap ridges.

CAUTION:

Be sure to remove all
traces of cleaning 
solution by thoroughly
rinsing the sleeve prior 
to replacing it into 
the reactor. Follow the
lamp/sleeve replacement
instructions.

CAUTION:

UV-C rays are present
when the unit is 
operating. Follow the
instructions carefully to
avoid injury to eyes and
skin. Only qualified 
persons should install 
or replace UV lamps 
or sleeves.

7. To remove the lamp from its

sleeve (Figure 5), use a glove or
cloth to support and hold on to
the sleeve. Unscrew the lamp
from the sleeve bolt. Be careful
not to drop the sleeve. If
required, place an adjustable
wrench on the flats at the side of
the sleeve bolt and a screw driver
shaft into one of the slots in the
top of the lamp end (Figure 6).

Lamp Installation

1. Ensure O-ring and seating area

are clean prior to assembly.
Place the O-rings and the sleeve
bolt on the quartz sleeve and put
the lamp into the quartz sleeve
(Figure 7). Be careful not to
angle the lamp while inserting it
into the quartz sleeve. If
excessive force is applied, the
outward pressure on the inside
edge of the quartz sleeve will
cause it to fracture. Slide the
lamp into the quartz sleeve until
the top of the sleeve meets the
bottom of the groove in the lamp
end. Screw the lamp end and
sleeve bolt together while
ensuring that the quartz sleeve
remains at the bottom of the
groove in the lamp end (Figure 7).
Once the O-ring begins to sit in

position, place a screwdriver
shaft in one of the slots in the
top of the lamp end and an
adjustable wrench on the flats at
the side of the sleeve bolt
(Figure 6). Further tighten the
lamp end 1/5

th

of a revolution. 

Caution:  Do not over -
tighten. Over tightening will
break the quartz sleeve. 
Caution: Do not lubricate 
any of the O-rings.

2. Ensure O-ring and seating area

are clean prior to assembly.
Carefully place the lamp/sleeve
assembly into the reactor.
Centre it with the spring in the
opposite end of the reactor and
screw the assembly into the
reactor. Once the O-ring begins
to sit in position, place an
adjustable wrench on the flats
of the sleeve bolt and tighten
sleeve bolt 

1

/

4

turn (Figure 8).

Caution: Over-tightening the
sleeve bolt will break the
quartz sleeve.

3. If you are attaching the harness

for the first time, place the
eyelet of the green/ yellow
ground wire and the red strain
relief wire onto the ground stud
of the reactor (Figure 9). Screw

the lock nut provided onto
the ground stud to secure the
connectors of the ground wire
and strain relief wire. 
Note: while tightening the lock
nut ensure that the eyelets are
turned sideways toward the
sleeve bolt. This is to ensure
that the eyelets and wires are
not sticking out and will be
covered by the grey plastic
cap. 

4. Push the plug onto the end of

the lamp while ensuring that
the male tab on the lamp end
meets with the female tab on
the plug (Figures 10 and 11).
Ensure the green/yellow
ground wire and the red
strain relief wire are tight
against the sleeve bolt so that
they will be covered by the
cap. Push or snap on the grey
plastic cap while ensuring that
the wires are not in the way of
the snap fingers or the
support ridges that are on the
inside of the cap (Figure 12).

5. If the sleeve required

cleaning, the UV sensor will
also need cleaning (if so
equipped). Refer to Cleaning
the UV Sensor section of
instructions (p.17).

Summary of Contents for Trojan UV Max

Page 1: ...n _______________________________________________________________________________________________________________________________ For service and lamp orders call your installer at ___________________...

Page 2: ...tandard 53 Drinking Water Treatment Units Health Effects shall be installed upstream of the system NSF Standard 55 defines waste water to include human and or animal body waste toilet paper and any ot...

Page 3: ...ensor has reduced detected UV intensity Coating on the UV sensor has reduced detected UV intensity Coating must be removed for correct operation Follow cleaning procedures in manual Coating must be re...

Page 4: ...amp harness before removing lamp from reactor 10 If the UV system malfunctions or fails which is indicated by the system s audible alarm and red LED light water must be boiled prior to consumption unt...

Page 5: ...lways disconnect the extension cord from the receptacle before disconnecting this system from the extension cord Never yank cord to pull plug from outlet Always grasp the plug and pull to disconnect T...

Page 6: ...ailure analysis Replacement lamps and parts provided under warranty will be sent to your Trojan dealer General Conditions and Limitations None of the above warranties cover damage caused by improper u...

Page 7: ...d Electrical Components Trojan warrants the structural hardware and electrical components to be free from defects in material and workman ship for a period of five 5 years from the date of purchase Du...

Page 8: ...nstallation or Replacement of UV Lamp Sleeve section to remove the lamp sleeve p 12 2 Clean the sleeve by using a commercial grade remover such as Lime A WayTM or CLRTM on a high quality lint free cot...

Page 9: ...n the attached cord may shorten the UV sensor s life Installation 1 Always disconnect the power to the power supply before installing servicing or maintaining the UV system To avoid injury avoid direc...

Page 10: ...0 or 60Hz Visual Alarm During normal operation the LED light will be green The LED is always on while the lamp is on The LED will turn amber after 11 months of operation or on the Plus models if the s...

Page 11: ...Sensor The UV sensor measures the amount of UV light reaching it allowing the system to monitor whether the intensity is above the minimum required for proper dis infection The sensor is factory calib...

Page 12: ...screw driver shaft into one of the slots in the top of the lamp end Figure 6 Lamp Installation 1 Ensure O ring and seating area are clean prior to assembly Place the O rings and the sleeve bolt on the...

Reviews: