25
Unit LEDs
LED
Condition
Status
PWR
Illuminated
Primary power is supplied to switch
Off
Primary power off or failure
RPS
Illuminated
Redundant power is supplied to switch
Off
Redundant power off or failure
ALM
Illuminated
External signal device will be activated through
terminal block ALM when there is any alarm.
Alarm for following conditions
Power lost (primary or secondary)
Abnormal voltage input
Off
No alarm to report
POST
Illuminated
Switch is ready or running
Blinking
Self-testing the device when power On
Off
Switch is not ready
SFP
(9~12)
Illuminated
SFP port link-up
Blinking
Activity (receiving or transmitting data)
Off
Port disconnected or link failed
1000
Illuminated
Port is operating in 1000Mbps speed
Off
Port is operating in 10/100Mbps speed
LNK/ACT
Illuminated
Ethernet link up
Blinking
Activity (receiving or transmitting data)
Off
Port disconnected or link failed
3.4.
USB Port
USB device can be inserted for auto firmware up-gradation. Switch auto-checks the firmware
version present in the USB device and upgrades if newer version of Firmware is present.
For example if you are running with Firmware version 1.0.0.S0 you need to upgrade the
firmware to version 1.0.1.S0 then you need to follow these steps.
1.
Create a folder with model name in USB (eg: NGI-M08C4-L2)
Note: don’t add ‘A’ in folder name.
2.
Insert new firmware file in that folder.
Note:
There should be only one firmware file in the folder. If there is more than one, the
firmware upgrade process will stop.
3.
Plug in USB drive to USB port of NGI-M08C4-L2