TMCM-1211 TMCL
™
Firmware Manual • Firmware Version V1.10 | Document Revision V1.00 • 2018-OCT-02
105 / 133
Number
Axis Parameter
Description
Range [Units]
Access
188
PWM
amplitude
Maximum PWM amplitude when switching to
stealthChop mode. Do not set too low. Values
above 64 recommended.
0. . . 255
RW
189
PWM scale
Actual PWM amplitude scaler (255=maximum
voltage). In voltage mode PWM, this value allows
to detect a motor stall.
0. . . 255
R
190
PWM mode
Status of stealthChop voltage PWM mode (de-
pending on velocity thresholds).
0 - stealthChop disabled
1 - stealthChop enabled
0/1
R
191
PWM
frequency
PWM frequency selection for stealthChop.
0 - f
PWM
= 15.625kHz
1 - f
PWM
= 23.426kHz
2 - f
PWM
= 31.250kHz
3 - f
PWM
= 39.024kHz
0. . . 3
RW
192
PWM autoscale
PWM automatic amplitude scaling for stealth-
Chop.
0 - User defined PWM amplitude. The current
settings do not have any influence.
1 - Enable automatic current control.
0. . . 1
RW
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany