TMCM-1211 TMCL
™
Firmware Manual • Firmware Version V1.10 | Document Revision V1.00 • 2018-OCT-02
31 / 133
3.6.7
STAP (Store Axis Parameter)
This command is used to store TMCL axis parameters permanently in the EEPROM of the module. This
command is mainly needed to store the default configuration of the module. The contents of the user
variables can either be automatically or manually restored at power on.
Info
For a table with parameters and values which can be used together with this
command please refer to dection
Internal function:
The axis parameter specified by the type and bank number will be stored in the
EEPROM.
Related commands:
SAP, AAP, GAP, RSAP.
Mnemonic:
STAP <parameter number>, <bank>
Binary Representation
Instruction
Type
Motor/Bank
Value
7
see chapter
0
0 (don’t care)
Reply in Direct Mode
Status
Value
100 - OK
0 (don’t care)
Example
Store axis parameter #6.
Mnemonic:
STAP 7, 6.
Binary Form of STAP 6, 12
Field
Value
Target address
01
h
Instruction number
07
h
Type
06
h
Motor/Bank
00
h
Value (Byte 3)
00
h
Value (Byte 2)
00
h
Value (Byte 1)
00
h
Value (Byte 0)
00
h
Checksum
0E
h
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at