![Trinamic TMCM-1211 TMCL Firmware Manual Download Page 18](http://html1.mh-extra.com/html/trinamic/tmcm-1211-tmcl/tmcm-1211-tmcl_firmware-manual_1163071018.webp)
TMCM-1211 TMCL
™
Firmware Manual • Firmware Version V1.10 | Document Revision V1.00 • 2018-OCT-02
18 / 133
Parameter Commands
Mnemonic
Command number
Meaning
SAP
5
Set axis parameter
GAP
6
Get axis parameter
STAP
7
Store axis parameter
RSAP
8
Restore axis parameter
SGP
9
Set global parameter
GGP
10
Get global parameter
STGP
11
Store global parameter
RSGP
12
Restore global parameter
Table 7: Parameter Commands
3.5.3
Branch Commands
These commands are used to control the program flow (loops, conditions, jumps etc.). Using them in direct
mode does not make sense. They are intended for standalone mode only.
Branch Commands
Mnemonic
Command number
Meaning
JA
22
Jump always
JC
21
Jump conditional
COMP
20
Compare accumulator with constant value
CSUB
23
Call subroutine
RSUB
24
Return from subroutine
WAIT
27
Wait for a specified event
STOP
28
End of a TMCL program
Table 8: Branch Commands
3.5.4
I/O Port Commands
These commands control the external I/O ports and can be used in direct mode as well as in standalone
mode.