c. Insert a strong wire or rod into the drain port, and briskly stir the fluid while it
is draining. This will stop bulky solids from blocking the drain port causing
liquid to remain in the pump. Flush the pump with clean water to remove
leftover solids.
E. CHECKING THE BEARING TEMPERATURE
Friction generated heat normally causes bearings to run at higher than normal
temperatures.
Normal temperatures for bearings range between 160º F (71º C) and 180º F (82º C).
Avoid testing bearing temperatures by hand because the measurement is inaccurate.
Instead, determine the temperature of the bearings by touching a contact-type
thermometer to the bearing housing then document the temperature for accurate
record keeping.
Bearings are nearing the point of failure when there is a sudden rise in bearing
temperature. Check for adequate viscosity of the bearing lubricant and be sure it is
at the appropriate level as noted in Section VI, LUBRICATION. Incorrect positioning
of the shaft can cause overheating of the bearings. Too much vibration can also
cause the bearings to overheat.
During initial pump start-up, the bearings may seem to operate at higher than normal
temperatures, however, continuing pump operation should reduce the temperatures
to normal operating range.
THIS SPACE LEFT BLANK INTENTIONALLY
Summary of Contents for 8-WSP
Page 62: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 62 ...
Page 63: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 63 ...
Page 64: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 64 ...
Page 65: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 65 ...
Page 66: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 66 ...