Figure 10
Figure 11
Generously lubricate the back cover O-rings with No. 2 grease. Remove and clean
all debris or scale from the pump casing contact surfaces. This could interfere with
or prevent a strong seal with the back cover.
Locate and loosen the 2 hand adjusting knobs in the coverplate until they are even
with the backside, machined surface of the coverplate.
Accurately position the coverplate over the 4 studs then slide it into the pump’s
casing. Use two diagonally positioned hand nuts that are opposite each other for
pushing the coverplate into the pump casing. Be sure the wearplate barely touches
Summary of Contents for 8-WSP