WSP™
DATA SHEET
WSP™ SELF-PRIMER PUMPS
WSP-D300_8
Rev. 3
01/09/20
© 2019 The Factory
6
WHEN A MANUAL SHUT-OFF VALVE IS INSTALLED IN A BYPASS LINE, IT MUST
REMAIN OPEN DURING OPERATION. CLOSING THE MANUAL SHUT-OFF VALVE
COULD CAUSE A PUMP, WHICH HAS LOST PRIME, TO CONTINUE TO OPERATE
WITHOUT REACHING PRIME. THIS COULD CAUSE DANGEROUS OVERHEATING OF
THE PUMP AND POSSIBLY RUPTURE THE PUMP CASING.
BEFORE SERVICING, ALLOW SUFFICIENT TIME FOR THE OVERHEATED PUMP TO
COMPLETELY COOL. ONCE THE PUMP HAS COMPLETELY COOLED, DRAIN THE
LIQUID FROM THE PUMP BY REMOVING THE CASING DRAIN PLUG. WHEN
REMOVING THE DRAIN PLUG, USE CAUTION. FAILURE TO DO SO MAY RESULT IN
INJURY. PLATES, COVERS, GAUGES, OR FITTINGS MUST NOT BE REMOVED FROM
AN OVERHEATED PUMP. LIQUIDS IN THE PUMP CAN REACH BOILING
TEMPERATURES AND PRESSURE INSIDE THE PUMP CAN CAUSE PARTS TO BE
EXPELLED VIOLENTLY.
BEFORE SERVICING, ALLOW SUFFICIENT TIME FOR AN OVERHEATED PUMP TO
COMPLETELY COOL. ONCE THE PUMP HAS COMPLETELY COOLED, DRAIN THE
LIQUID FROM THE PUMP BY REMOVING THE CASING DRAIN PLUG. WHEN
REMOVING THE DRAIN PLUG, USE CAUTION. FAILURE TO DO SO MAY RESULT IN
INJURY. PLATES, COVERS, GAUGES, OR FITTINGS MUST NOT BE REMOVED
FROM AN OVERHEATED PUMP. LIQUIDS IN THE PUMP CAN REACH BOILING
TEMPERATURES AND VAPOR PRESSURE INSIDE THE PUMP CAN CAUSE PARTS
TO BE EXPELLED VIOLENTLY.
WHEN PERFORMING EQUIPMENT MAINTENANCE OR IF THE PUMP IS TO
REMAIN OUT OF SERVICE FOR A PERIOD OF TIME, THE EQUIPMENT
ELECTRICAL SERVICE MUST BE DISCONNECTED WITH AN APPROVED
LOCKOUT AND KEY. FAILURE TO LOCK OUT THE EQUIPMENT MAY RESULT IN
INJURY.
1.
IF OVERHEATED, THE PUMP MUST BE ALLOWED TO COMPLETELY
COOL BEFORE ATTEMPTING ANY PROCEDURES.
2. CHECK THE TEMPERATURE BEFORE OPENING ANY COVERS,
PLATES, OR PLUGS.
3. ENSURE THAT SUCTION AND DISCHARGE VALVES ARE CLOSED.
4. SLOWLY AND CAREFULLY VENT THE PUMP.
5. DRAIN THE PUMP.
Summary of Contents for 8-WSP
Page 62: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 62 ...
Page 63: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 63 ...
Page 64: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 64 ...
Page 65: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 65 ...
Page 66: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 66 ...