L. INSTALLING THE ROTATING ASSEMBLY
Lubricate the bearing housing O-ring with light grease then install by easing the
rotating assembly into the pump casing. Use the installation tool for this procedure
being careful to avoid damaging the O-ring.
Use the same rotating assembly adjusting shim thickness as those removed. Attach
the rotating assembly to the pump casing with the hardware.
Refer to Section IV. Part I. Installing and Adjusting the coverplate in these
instructions to accurately set impeller and wearplate clearance.
M. INSTALLING THE SUCTION CHECK VALVE
Carefully inspect the check valve assembly for wear and damage. If it is worn or
damaged, replace it.
NOTE:
Only replace the check valve assembly as a total unit. Parts are not sold
individually.
Enter the case through the coverplate opening with the check valve. Place the check
valve adaptor in the mounting slot. This is located in the suction flange. Match the
adaptor to the flange hole, and attach the check valve with the check valve pin.
NOTE:
If you removed the suction or discharge flanges, replace both gaskets and
attach them to the pump casing with their attaching hardware.
N. INSTALLING & ADJUSTING THE COVERPLATE
Center the wearplate on the coverplate and attach it with its hardware if it was
previously removed. To prevent binding, it is critical for the wearplate to be
concentric when installing on the coverplate.
You can easily adjust clearance between the wearplate and the impeller without
using hand tools. The ideal clearance between the wearplate and the impeller is
from .010” to .015”.
Summary of Contents for 8-WSP
Page 62: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 62 ...
Page 63: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 63 ...
Page 64: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 64 ...
Page 65: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 65 ...
Page 66: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 66 ...