Figure 6
H. REASSEMBLING THE TWO-PIECE BEARING HOUSING
Replace and lubricate the O-ring. Place the inner bearing housing half into the outer
bearing housing half and install all the bolts and lock washers (See Figure 6). Torque
the bolts to 67 lb-ft for dry threads and 40 lb-ft for lubricated threads.
I. REASSEMBLING & INSTALLATING THE SHAFT & BEARING
Soak a soft cloth in cleaning solvent and wipe down the bearing housing, the shaft,
and all component parts with the exception of the bearings. Check all parts for
damage or wear and replace any that are defective.
BEFORE USING ANY CLEANING SOLVENTS CAREFULLY READ AND FOLLOW ALL
PRECAUTIONS PRINTED ON THE SOLVENT CONTAINER. CLEANING SOLVENTS ARE
KNOWN TO BE TOXIC AND FLAMMABLE AND ARE ONLY TO BE USED IN WELL-
VENTILATED AREAS AWAY FROM EXCESSIVE HEAT, SPARKS, AND FLAMES.