85
Model Three - Operation Manual
If the Model Three is turned on during an Auto test program, the
program status screen appears to indicate the Auto test status. The
program may be stopped by pressing the
F
1
F
1
(STOP)
key.
A file containing all test records is created for each test time and
automatically saved. The file name is the Auto test program name
followed by an alphabetical assignment (beginning with A) for each test
time file to indicate they are 24 HR Auto test files. This is displayed in the
Model Three file directory along with the date and time (See
File Saving
and Viewing
in this chapter).
If a Limit test is part of a 24 HR Auto test program,
a 24 Hour Video Deviation report (Rep_24) is also
created and saved after the last test sequence.
This data record lists the maximum video
deviation over all time tests for each channel
along with a Pass (P) or Fail (F) indication for the
channel based on the Limit test parameter setup
at the time the Auto test was performed.
If you wish to save the Auto test program for later use without running
the entire program now, you can start the test and then press the
F
1
F
1
key
to exit.
The new Auto test program is added to the Auto test directory with the
program name entered in
STEP 1
.
Up to seven Auto test programs may be created and saved. From the
Auto test directory, a program may be deleted by using the
__
and
keys to highlight the program name and pressing the
F
2
(DEL)
key.