59
Model Three - Operation Manual
Frequency Spectrum Scanning
The Model Three can be set to display spectrum measurements with
spans ranging from 2.5 to 62.5 MHz. It can also be set for a full spectrum
scan of the base channel plan with sampling at each video carrier
frequency or center frequency of digital channels.
For further information on Transmission operation, see
Chapter 6:
Advanced Operation, Transmission Characteristic Test
.
The following information is for normal (absolute) spectrum scanning.
Transmission mode is set up in the
MEASUREMENT menu. Since the following
data is for normal (absolute) spectrum
scanning, Transmission should be set to OFF
in the MEASUREMENT menu (see Chapter 4:
Setup, Measurement, Transmission).
The Model Three can show spectrum data with
absolute measurements, or it can store data
for comparative tests using the Transmission
feature.
While in the Spectrum mode, you can use
Fast Setup (press the
SET
SET
7 STU
key once) to go
directly to the Measurement Setup parameters
including Transmission.