Revision: 0
FlexxPump1 B
User Manual
47
EN-
Carry out the work as described above (steps 1 to 4).
Ü
If an error was displayed in the LCD before changing the cartridge or battery, the
message will now disappear, as will the flashing red LED. A separate confirmation is not
necessary. The green LED flashes briefly every 30 seconds.
Ü
The FP1 B automatically returns to the last active mode (ON or OFF) before the
completion of this work.
If the empty state of the cartridge (Error E1) was reached during a dispensing cycle,
it is automatically interrupted and continued automatically after completion of the work
explained above.
7.3
Disposal
When disposing the FP1 B, empty or opened cartridges and batteries, observe the
relevant national regulations in force.
When disposing the FP1 B, observe the relevant safety data sheets and disposal
instructions for the individual components.
Batteries cannot be recharged.
It is not possible to refill empty lubricant cartridges.