Revision: 0
FlexxPump1 B
User Manual
19
EN-
6.2
Factory settings
FP1 B is always delivered ex works with the following settings:
operating mode Hour-Mode -h-
Mode
OFF
FP1 B is switched off
The factory settings foresee using the FP1 B in the Hour-Mode -h-. If you want to
operate the FP1 B in Empty-Time-Mode Et, you have to make changes in the SET-
Menu of the FP1 B to set the Empty-Time-Mode Et (chapter 6.3.6).
Dispensing time
h = 6
The dispensing time is 6 hours.
Number of cycles
c = 1
The number of cycles is one (1) stroke
during
the
dispensing
time.
The default settings in the Hour-Mode result in an emptying time (service life) of 195
days (= 6.4 months) for a full 125 ml lubricant cartridge, provided that the FP1 B is per-
manently switched on and no special dispensations have been made. Within approx. 6
hours, the FP1 B will deliver one donation per stroke (0.16 cm³).
Verify that the default settings are appropriate for your application and that the lubri-
cation point is supplied with the correct amount of lubricant per time unit.
If this is the case, you can operate the FP1 B with the default settings in the Hour-Mode
-h-.
If this is
not
the case, change the values for the dispensing time t and number of cycles
c accordingly; see chapter 6.3.8 for an explanation of how to make these changes.
To use FP1 B, it must first be properly mounted and installed and then switched on.
Installation is very simple and described in detail in chapter 5.2; switching on is descri-
If you order a special version of FP1 B from the factory, the information contained in
the supplement is authoritative for you!