Revision: 0
FlexxPump1 B
User Manual
42
EN-
Before starting any maintenance work, inform yourself about the general safety
instructions (see Chapter 2) and observe the relevant local and operational safety
regulations.
Do not deactivate any protective device without authorization!
The following maintenance schedule must be observed for the FP1 B:
Maintenace
Commis-
sioning
After 500
hours or after
3 months
Every
year
If required
Cleaning
x
x
x
x*
Visual check
x
x
x
x*
Battery change
x**
x***
x*
Cartridge change
x**
x***
x*
*
Depending on operating conditions and lubricant consumption
**
Depending on delivery status (ordered version)
***
Recommendation after 2 years at the latest
LCD
Name
Description
Remedy
Error
E4
Fatal error
Disassemble the FP1 B and
return it to the manufacturer
together with the lubricant
cartridge and a description of
the fault.
A fatal error usually occurs
in the electronics of the FP1 B
and cannot be repaired by you
on site.
The address of the manufac-
turer can be found in chapter
I.II.
E4
7.
Maintenance and disposal
7.1
Maintenance schedule