Revision: 0
FlexxPump1 B
User Manual
37
EN-
Ü
The LCD as well as the green LED flashes twice and the number of cycles c is dis
-
played in the LCD.
Insert the activation and programming key into the hole provided on the underside of
the FP1 B.
The PRO-Menu can only be reached from the ON mode (FP1 B switched on).
When you enter the PRO-Menu, you will return to the ON mode.
If you have made changes to the values of the dispensing time h or the values of the
number of cycles c in the PRO-Menu and the FP1 B is otherwise ready for operation
(battery full and inserted as well as a cartridge fitted), the FP1 B will immediately start
with the calculated waiting time until the next dispensing.
Observe the back pressure values displayed on the LCD if they are of interest to
you.
During the dispensing process, the green LED lights up; in addition, the counterpres-
sure for the stroke is displayed in the LCD.
The parameters that can be set for the dispensing time h and the number of cycles c
and their respective permissible values are specified as follows:
h :=
Dispensing time
in hours (h).
The dispensing time can be set between 1 | 2 | 3 | ... | 99 hours.
The time counter integrated in the microelectronics of the FP1 B starts coun-
ting the dispensing time h at the end of a successful and fully completed
dispensing cycle.
c :=
Number of cycles
within a dispensing cycle (c).
The number of cycles c can be set between 1 | 2 | 3 | ... | 10 strokes.