Revision: 0
FlexxPump1 B
User Manual
43
EN-
Clean the FP1 B from dirt using suitable cleaning agents (e.g. absorbent towels,
cloths).
NOTICE
Compressed air can damage the seals of the FP1 B as well as
transport dirt and foreign bodies into the FP1 B or the lubri-
cant.
§
Do not use compressed air to clean the FP1 B.
7.1.1 Visual check
Reinstall all safety devices and make sure that no tools remain in the danger area.
Check that the FP1 B is turned on.
Carry out a "Quick Check" (test run) using the RUN command (section 6.3.7).
Check the entire lubrication system (FP1 B and any connected accessories including
tubes and distributors) for external damage (e.g. loose or loosened tubes) by a thoro-
ugh and conscientious visual inspection.
Check the condition of the lubrication point for correct supply of lubricant.
Replace damaged or defective parts immediately to ensure permanent lubrication.
Check the filling level of the cartridge on the FP1 B.
Check possible error messages on the FP1 B and remedy the causes accordingly.
7.1.2 Cleaning
7.1.3 Recommissioning after maintenance