Revision: 0
FlexxPump1 B
User Manual
30
EN-
6.3.4 INF-Menu operating mode Hour-Mode -h-
The INF-Menu is used to inform the user about the firmware used in the FP1 B and the
settings made and currently active (values of the adjustable variables t and c that can
be changed in the PRO-Menu).
In the INF-Menu nothing can be changed by the user. The values of the parameters are
displayed in a fixed order.
b
Alphanumerical name of the FP1 B firmware
h
set value of variable h dispensing time
c
set value of variable c number of cycles
125
value of the size of the lubricant cartridge
Remove the activation and programming key from the bottom of FP1 B and place it
on the action area.
Hold the activation and programming key on the action surface. The yellow LED lights
up. Leave the activation and programming key on the action area until INF is displayed
in the LCD. Remove the activation and programming key from the action area as long
as INF is displayed in the LCD. The yellow LED disappears; the LCD flashes together
with the green LED twice.
Ü
FP1 B informs you optically on the LCD about the set values.
Insert the activation and programming key into the hole provided on the underside of
the FP1 B.
The INF-Menu can only be accessed from the OFF mode (FP1 B is switched off).