![Treedental TR-KID-7 Instructions For Use Manual Download Page 22](http://html1.mh-extra.com/html/treedental/tr-kid-7/tr-kid-7_instructions-for-use-manual_1155111022.webp)
-20-
Press the key of each group, the indicator light turns on and enter into the memory procedures of this group; press one of
such three memory keys again, the patient chair may move to the corresponding memory position. Please refer to “
○
10 set key”
for the instructions of self-defining the chair position.
Note:
In case of pressing other function keys while the patient chair is moving, this key’s function will stop automatically.
○
9 Reset position
Press “RESET” key, the patient chair decilnes to the lowest position and the backrest fore rakes to the foremost position.
Press continues button. The dental chair will go up/down/tilt forward/backward, when reaching required position
Note:
Press any button duuing its moving , the movement will stop.
○
10 Set key
a) Time setting of water supply
Step 1: press “SET” key, the indicator light turns on.
Step 2: press “
” key until the water supply to the demanded amount.
Step 3: press “SET” key again, the indicator light turns off, setting fisish.
Note:
This procedure is only setting the time of water supply , if tap water changes , please reset the time .
a) Memory position set of the patient chair
Step 1: press “SET” key, the indicator light turns on.
Step 2: press “
”key or “
” key (press one of them or neither key) to adjust the chair’s height, and release the key until to
the required position.
Step 3: press “
” or “
” key (press one of them or neither key) to adjust the backrest’s angle, and release the key until to
the pre-set position.
Step 4: press any key of A, B, C group, and press any key of such three memory chair positions.
Step 5: press “SET” key, the indicator light turns off, and the set is completed. The required chair position has been memorized in
the corresponding memory group keys.
2. Emergency stop switch
To make an emergency stop caused by an accident during the movement process, one-push the “emergency button”
.
After pressing the emergency switch, all the mains power will be interrupt. If continuous movement is needed, turn this switch
clockwise. The machine will start to work again if the switcher leases automatically.
3.
Assistant tray controlling panel
1.2.3.4 patient chair position
5. water supply
6. Cuspidor water rushing
7. Constant temperature hot water
Please refer to the “instructions of the key panel” on Page 9
Summary of Contents for TR-KID-7