Chapter 7 Commands
TransCore Proprietary
7–117
Reader response:
Done
63 Reset Reader
See
“526 Display I/O Status” on page 7–105, “620N Set Output Control” on page 7–116,
Output Pulse Duration” on page 7–125.
Command
#63
resets the power fail bit, stores non-volatile memory (NVM) parameters, clears all buffers,
resets tag uniqueness, turns off both output lines, transmits the sign-on message, and returns to the data
mode.
Note:
This command does not reset any other configuration parameters.
Reader response:
Model E4 Series Ver X.XX SNSSSSSS
Copyright 2008 TransCore
where
X.XX
Version number
SSSSSS
Serial number of the unit, skipping the first and fourth character printed on the reader
product label.
640N RF Control
Command
#640N
directly controls the RF module. The
N
value controls the RF power as shown in
.
Table 31 RF Control Commands
Command
RF State
6400
Turns off RF
6401
Turns on RF
Command
#6400
disables RF-by-input control command #
641 Select RF-by-Input Control
.
Reader response:
Done
641 Select RF-by-Input Control (Factory Default)
Command
#641
configures the reader for RF-by-input control. The reader automatically turns on RF
when it detects a presence through sense0. The reader turns off RF according to the selected RF control
algorithm (
#692N Select RF Control Algorithm
).
Reader response:
Done