Table 56 Encompass 4 Reader Commands Listed Numerically
Number
Command Name
Reader Message
60NN
Set reader ID number NN = 00 to FF
Done
6000
Set reader ID number to 00 (default)
Done
610
Select basic protocol (default)
Done
611
Select ECP protocol
Done
612NN
Select ECP Timeout
Done
612FE
Set ECP timeout = 12.7 sec (default)
Done
612FF
Disable ECP timeout
Done
613
Enable data inquiry protocol
Done
614N
Select Flow Control Option
Done
6140
Disable flow control
Done
6141
Enable software flow control (default)
Done
6142
Enable hardware flow control
Done
6170
Disable echo mode
Done
6171
Enable echo mode
(default)
Done
620N
Set output control
Done
6200
Turn off both output ports
(default)
Done
6201
Turn off output1, turn on output0
Done
6202
Turn off output 0, turn on output1
Done
6203
Turn on both output ports
Done
621
Select predefined output mode (default)
Done
63
Reset reader
Model E4 Series Ver
X.XX SNSSSSSS
Copyright 2008
TransCore
640N
RF Control
Done
6400
Turn off RF
Done
6401
Turn on RF
Done
641
Select RF-by-input control (default)
Done
642NN
Select RF operating frequency
Done
643NN
Set ATA operating range (Distance)
Done
6431F
Set ATA operating range to longest range (default)
Done
Appendix D Command Quick Reference