Chapter 7 Commands
TransCore Proprietary
7–105
525 Display Communications Protocol Status
Command
“525 Display Communications Protocol Status” on page 7–105, “610 Select Basic
Communication Protocol (Factory Default)” on page 7–114
, Command
“614N Select Flow Control Option”
“612NN Select Error Correcting Protocol Timeout” on page 7–114
.
Reader response:
ECPS P<0 to 2> T<01 to FF> X<0 to 2> S0
where
P0
Basic protocol enabled (factory default)
P1
ECP enabled
P2
data inquiry protocol enabled
Txx
ECP timeout where xx = 01 to FE (hexadecimal) Timeout (ms) = 50 * xx
If xx = FF timeout disabled
X0
Flow control disabled
X1
Software flow control enabled (factory default)
X2
Hardware flow control enabled
S0
start of message character is
#
For example, if factory default settings are assigned, the reader message is:
ECPS P0 TFE X1 S0
which means basic protocol enabled, an ECP timeout of 254 (12,700 ms, 12.7 sec), software flow control
enabled, and start of message character is
#.
526 Display I/O Status
See
“620N Set Output Control” on page 7–116, “621 Select Predefined Output Control (Factory Default)”
on page 7–116, “67N Set Output Pulse Duration” on page 7–125.
Command
#526
displays the current input/output (I/O) status. The reader message indicates whether
outputs are being controlled externally by the host through Command
#620N Output Control
or
internally through Command
#621 Predefined Output Mode
. It also displays the current status of two
outputs, two inputs, and the selected output pulse duration that is set by Command
#67N
.
Reader response:
C<0 to 1> O<0 to 3> I<0 to 3> D<0 to F>
C0
Host controls outputs
C1
Predefined output mode
O0
Both outputs off
O1
Output0 on
O2
Output1 on
O3
Both outputs on