![Transcell Technology TC-2005 Series Setup & Operation Manual Download Page 22](http://html1.mh-extra.com/html/transcell-technology/tc-2005-series/tc-2005-series_setup-and-operation-manual_1150705022.webp)
5.4.3 EXITING THE USER MENU
1. Push the ZERO key a few times to get to the “-- A --“ level, then press the ZERO key
once more. The display will go through a digit check, then settle into Normal Operating
mode. All front panel keys will now return to their normal mode of operation.
NAME/CO
DE
DESCRIPTION CODE/VALUE
A1
Baud Rate
Selects the baud rate for data transmission through the serial port.
1200 2400
4800
9600
√
A2
Data Bits and
Parity
Selects the number of data bits and parity of serial transmission.
"8n" = 8 data bits with no parity bit
"7O" = 7 data bits with odd parity bit
"7E" = 7 data bits with even parity bit
8n
√
7O
7E
A3
COM Port
Device
Selects the device and function of the COM1 and COM2 serial ports:
"0" = Printer (COM1)
“1” = TC Scale for APW Download (COM2)
“2” = Scanner (COM2)
“3” = Computer (COM2)
0
√
1
2
3
A4
Printer Type
Selects the type of printer connected to COM1:
"0" =Non-barcode (Text) Printer (MP-20, Epson TM295,)
"1" = Barcode Printer (Eltron 2742, 2842)
0
1
√
A5
Display Check
Actuates the function that illuminates all digit segments, decimal
points, and LCD annunciators in a test sequence. Pressing the
TARE
key to scroll down one level begins the test sequence.
Press
TARE
key
to begin sequence
A6
Custom Unit
Actuates the function that allows you to enter a multiplier for the
custom unit. Pressing the
TARE
key to scroll down one level begins
the test sequence.
(1.0)
√
A7
ID No. Entry
Actuates the function that allows entry of a one ID No. up to 6
characters long. Pressing the
TARE
key to scroll down one level
begins the sequence.
(123456)
√
A8
Set Time
Actuates the function that allows entry of the current time. Pressing
the
TARE
key to scroll down one level begins the sequence.
Press
TARE
key
to begin sequence
A9
Check Time
Allows you to check the present time set on the scale. Pressing the
TARE
key to scroll down one level begins the sequence.
Press
TARE
key
to begin sequence
A10
Set Date
Actuates the function that allows entry of the current date. Pressing
the
TARE
key to scroll down one level begins the sequence.
Press
TARE
key
to begin sequence
Table 5-2: User Menu Descriptions – A1 to A10