R2
Grads
R5
Calib. Unit
lb kg
500 .... 50000
R3
Dsp. Div.
1
2
5
R4
Dec. Pt.
0 0.0 0.00 0.000 0.0000 00
R1
Remote Scale Enable
OFF ON
R6
Auto Switch
OFF ON
Figure 5-2: Remote Menu Chart
5.3.3 EXITING THE REMOTE MENU
1. Push the ZERO key a few times to get to the “-- R --“ level, then press the ZERO key once more.
The display will go through a digit check, then settle into Normal Operating mode. All front panel keys
will now return to their normal mode of operation.
NAME/CODE DESCRIPTION CODE/VALUE
R1
Remote Scale
Enable
Used to enable or disable the remote scale.
"OFF" = Disable remote scale "ON” = Enable remote scale
OFF
√
ON
R2
Graduations
Specifies number of full-scale graduations. Value should be
consistent with environmental limits on the useful system resolution.
500 1,000
1,500 2,000
2,500 3,000
4,000
5,000
√
6,000 8,000
10,000 12,000
20,000 30,000
40,000 50,000
R3
Display
Divisions
Determines the desired weight increments. Value should be
consistent with legal requirements.
1
√
2
5
R4
Decimal Pt.
Determines location of the decimal point.
0
√
0.0
0.00 0.000
0.0000 00
R5
Calib. Unit
Selects the primary base unit to be used in the calibration process.
Also the default unit for normal operation.
"1" = primary unit is lb. "2" = primary unit is in kg.
1
√
2
R6
Auto Switch
Enable
Used to enable or disable the auto switch channel feature.
"OFF" = Disable auto switch "ON" = Enable auto switch
OFF
√
ON
19