6.20
Stepper Current Setting (OLD Stepper Drivers)
Set multimeter on Vcc:
•
Remove fan blowing on the motherboard to gain fully access to stepper drivers
•
Black probe on extreme right PWR screw terminal (-)
•
Red probe on driver trimmer (small screw-like metal device on top of stepper drivers)
•
Readout on E0/E1/E2 = 0.45 V
•
Readout on X / Y = 0.75V
•
Readout on Z = 1.15V
•
Put back the fan
•
Check that all connectors are correctly and safely seated
Figure 6.20.1 Multimeter Probe Placement