![Tracker Off-Road EViS 2020 Repair And Service Manual Download Page 107](http://html1.mh-extra.com/html/tracker-off-road/evis-2020/evis-2020_repair-and-service-manual_1147189107.webp)
B
FAULT TESTING
Read all of SAFETY and this section before attempting any procedure. Pay particular attention to Notices, Cautions, Warnings and Dangers.
93
Repair and Service Manual
10002660
Main Menu Definitions
•
PARAMETERS - Shows vehicle profile setting and
adjustability.
•
MONITOR - Shows vehicle real-time diagnostics.
•
DIAGNOSTICS - Shows active and past faults.
NOTICE: The programmer does not request confir-
mation before deleting fault code history. Pressing
“DELETE ALL” will permanently remove any histori-
cal codes.
•
PROGRAMMING - Shows parameter setting
uploads and downloads.
•
SYSTEM INFO- Shows controller information.
•
HHP SETTINGS- Shows handheld information and
adjustment.
Menu
Submenu 1
Submenu 2
Submenu 3
Data Range
Default value
Parameters
Reset Controller
0 - 1
0
Monitor
Solenoid Coil
On - Off
On
Rear Node Select
On - Off
On
Solenoid PWM
0-100
0%
Rear Controller
Run/Tow Switch
On - Off
Key Switch or Charger
On - Off
Off
Economy Mode Switch
On - Off
Off
Forward Switch
On - Off
Off
Reverse Switch
On - Off
Off
Throttles
Raw Primary Throttle 0.00 - 5.00
0.73V
Mapped Primary
Throttle
0 -1 00
0.00%
Raw Redundant
Throttle
0.00 - 5.00
0.37V
Mapped Redundant
Throttle
0 - 100
0%
Inputs
Throttle Command
0 - 100
0%
Mapped Throttle
0 - 100
0%
Throttle Pot
0.00 - 5.50
0.73V
Pot2 Raw
0.00 - 5.50
0.37V
Interlock
On - Off
Off
Analog 2
0.00 - 10.00
1.24V
Outputs
5 Volts
0.00 - 6.25
4.94V
12 Volts
0.00 - 12.00
12.42V
Ext Supply Current
0 - 200
63mA
Pot Low
0.00 - 6.25
0.20V
Battery
BDI
0 - 100
75%
Capacitor Voltage
0.0 - 105.0
3.1V
Key Switch Voltage
0.0 - 105.0
77.0V
Motor
Motor RPM
-12000 -12000 0 RPM
Temperature
-100 - 300
29
o
C
Motor Speed A
-12000 - 12000
0 RPM
Motor Speed B
-12000 - 12000
0 RPM
Fig. 5 CURTIS Handheld Controller Main/Sub-menus