16
Target change while lifting up
Only before the forks have stopped at the target, extra
clicks can change the target to the next level up to the
highest target memory.
But after they have once stopped at a target, one extra
click cannot change the target to the next and the forks
cannot be lifted until the lift lever has returned to neu-
tral.
Note:
In such a case that the lift lever has already operated,
the target can be changed only up to the highest mem-
ory in all the memories.
Neither cancel of the target nor change of the target to
the lower level can be done by any clicks on the high-
est screen.
Setting function
Operators can use the setting menu for “Automatic
Height Control” on the operator’s menu screen
(“HEIGHT SET “ menu).
Operator must lift the forks up to the height that they
want to memorize. At this time, the setting screen dis-
plays the height relation between three memories and
the current height. So operators can select the memory
to overwrite out of A, B or C by using switch (2) and
switch (3).
Continuing to press switch (1) “SET” for two seconds
can overwrites the current height on the selected mem-
ory. If the memory has been overwritten, “OK” screen
is displayed and the setting screen refreshed about the
height relation is displayed by pressing the switch (4).
Note:
The height position cannot be memorized near the
heights memorized in the other two memories.
(On design it is within 100mm, but it may increase on
various conditons).
In addition in the operator’s menu, all three memories
can be cleared simultaneously.
The screen to clear all the memories is displayed by
selecting the menu “HEIGHT SET CLR” by using the
switch (1) and switch (4) on the operator’s menu
screen.
Continuing to press switch (1) “CLR” for two seconds
can clear all the memories on the screen.
Note:
The height position memories of the height limiter and
maximum height limiter cannot be cleared by this pro-
cedure.
switch(1) switch(2) switch(3) switch(4)
switch(1) switch(2) switch(3) switch(4)
Interference avoidance with the load meter
If the multi-function display deluxe is taken as an
option, the load display switch plays two roles for load
meter switch and the height selector switch.
So the controller judges the period of pushing the but-
ton and controls the load meter and Automatic Height
Control as follows.
(1)
Long operation of the load display switch before
lift-up
Before the lift lever is operated upward, the long push
(over 1 second) can display the load meter.
The favorite height memory is kept at the selected
position for 10 second from the moment when the
switch is turned off.
(2)
Long operation of the load display switch while
the automatic height control is activating
After the Automatic Height Control has activated, all
the long push (over 1 second) is ignored and the load
meter is not displayed.
Of course the target memory is kept at the selected
position.
Interference avoidance with the height limiter func-
tion
If the “maximum height limiter” or the “height limiter”
is set, there is a case that the memorized positions of
the Automatic Height Control are higher than the lim-
ited height by them.
The higher memory positions are ignored and cannot
be selected. In addition, they are not displayed on the
screen.
Note:
The ignored height memories become available again
after the height limiter is disabled.
(En-15)
Summary of Contents for 8FBE18T
Page 1: ......
Page 53: ...53 En En 52...