12
Load meter and over set load alarm
(Multi-function Display Deluxe Only)
Load Meter
Pressing the load display switch on the lift lever
switches the general screen to the load meter screen,
displaying the load weight in unit of 0.01 t.
Weights less than 100 kg are displayed as 0.00 t.
(Keeping pressing the switch continues to display the
screen, but load meter screen doesn’t appear while
vehicle speed is detected.)
Conditions for measuring
The mast should be vertical and the forks height should
be at height of approximately 500 mm for measuring.
Note:
•
This function is not available for business dealings
and certifications.
•
It detects the lift cylinder pressure to facilitate
measurements, so it should not be used to judge
whether the overload value is near the allowable
value.
•
At the highest end, residual pressure is generated
when the relief stops, and an overly large value is
displayed.
Load meter screen at high-lift height
The accuracy drops because of the influence of the
mast deflection and friction at the high lift position, so
the screen changes in order to tell the operator to meas-
ure at the lower height.
Of course this screen is displayed on the models with
V mast at the high lift position
Over set load alarm
An administrator can set the value to activate the
“Over Set Load Alarm”.
If the detected weight goes over the preset value when
the operator is displaying the load meter by the load
display switch, the lights of over load indicator and the
buzzer sound inform the operator.
If a customer wishes the alarm to activate always, the
technician can change it into such operation specifica-
tion in masked function.
However in such operation specification, a lighter
weight than the set value wrongly activates the alarm
frequently because of fluctuations of load while driv-
ing, or because of increased load while lifting.
Note:
This function should not be used to judge the allowable
load.
Setting screen
Press switch (1) on the general screen for more than 2
seconds will display the setting menu screen.
Select an item with switch (1), and press switch (4) to
display each setting screen.
Note:
If the administrator sets the menu lock ON, the setting
menu screen cannot be displayed.
Low speed setting screen
The limit speed of the Low-speed setting function can
be changed.
Switch (2): Setting traveling speed down.
Switch (3): Setting traveling speed up.
Switch (4): Returning to setting menu screen.
It is adjustable from 2 to 50 km/h with a step of 1 km/
h.
If the operator set the speed to more than 50km/h, the
low speed function is disabled.
In that case “OFF” is displayed.
This screen is not displayed in the PIN Code Entry
System model.
Over speed alarm setting screen
The speed to activate the over speed alarm function
can be changed.
Switch (2): Setting traveling speed down.
Switch (3): Setting traveling speed up.
Switch (4): Returning to setting menu screen.
It is adjustable from 5 to 50 km/h with a step of 1 km/
h.
If the operator sets the speed to more than 50km/h, the
low speed function is disabled. In that case “OFF” is
displayed.
This screen is not displayed in the PIN Code Entry
System model.
Automatic height control setting screen
(Height Selector model only)
For details, see “Automatic height control”.
Height limiter setting screen
(Height Selector model only)
For details, see “Height limiter”.
switch(1) switch(2) switch(3) switch(4)
(En-11)
Summary of Contents for 8FBE18T
Page 1: ......
Page 53: ...53 En En 52...