www.toyorobot.com
19
4-2 Installation environment and base requirement
The environmental requirement or restriction for Toyo
’
s actuator is:
Item
ETH
ECH
Surrounding
temperature while
operating.
0~45
℃
0~45
℃
Surrounding
humidity while
operating.
35~85% RH
35~85% RH
Maximum
installation
height.
0~1000m above sea level.
0~1000m above sea level.
Surrounding
Avoid the following environment:
Near water, cutting liquid, dust, metal chips or solvents.
Environment filled with corrosive gas or liquid.
Environment filled with flammable materials in any forms.
Locations where surrounded by electro-magnetic
disturbance, statistic or radio-wave emitting.
Locations where there are vibration sources nearby or
easily collided.
Please provide enough space for service.
Installation base requirement:
Correct installation base
Incorrect installation base
a)
The installation base should be solid and rigid to sustain the vibration
from operation, also must be able to sustain the weight of the actuator
plus the working piece.
b)
The installation base must be even, within the range of
±
0.05mm/500mm.
c)
The installation base must be bigger than the mounting surface, and has