www.toyorobot.com
13
1-7
Automatic operation
a)
Before start, please check the following:
There is no one inside the safeguard enclosure.
The programming unit and tools are in their specified locations.
The alarm or the error lamps of the actuator and the equipment has not been
triggered.
The safeguard enclosure is securely installed with safety interlock active.
b)
Observe the following during automatic operation or in case there are errors
occurred.
After the automatic operation has started, check the operation status and
warning lamps to ensure that the actuator is in automatic operation.
Never enter the safeguard enclosure while automatic operation is active.
In case an error has occurred within the actuator or peripheral equipment,
obey the following procedure before entering the safeguard enclosure.
1.
Activate the emergency stop to stop the actuator completely.
2.
Place a sign on the starting switch, indicating that the actuator is
been inspected, this is to prevent others from touching the start switch
or restart the actuator.