tousek
/ EN_PULL-TSA_03 / 25. 03. 2020
- 11 -
Main layer
Settings
LED display
Menu items
LED dis-
play
Settings
P0
see page 12
radio
0
1
2
3
learn impulse
learn partial opening
delete individu.
delete all
(no)
(yes)
P1
see page 13
mounting direction
0
1
<<<--- left
--->>> right
P2
see page 13
impulse button
0
1
2
3
4
OPEN/STOP/CLOSE
OPEN/CLOSE/OPEN
OPEN abort PT
OPEN extend PT
DEADMAN FUNCTION
The selected
setting applies
to both - impulse
and pedestrian -
buttons
P3
see page 15
photocells
0
1
2
3
not active
reverse during closing
Stop - after release open
during clos.stop then closing
P4
see page 16
safety edges
0
1
2
3
not active
only main edge
only side edge
MSE and SSE
P5
see page 16
max. force
0–9
0 (weaker) ...9 (stronger)
= 7
P6
see page 17
ARS-response time
0–8
0 (sensitive) ...8 (insensitive)
= 4
P7
see page 17
soft stop way
0–9
0 (x 10cm) ...9 (x 10cm) soft stop way
= 5 (x10cm)
P8
see page 17
operation mode
0
1
2
3
4
5
6
7
8
9
impulse mode
aut. closing 5s
aut. closing 15s
aut. closing 30s
aut. closing 45s
aut. closing 60s
aut. closing 90s
aut. closing 120s
aut. closing 300s
aut. closing 600s
P9
see page 17
prewarning time
0
1
2
switched off
4s only CLOSE
4s OPEN and CLOSE
PA
see page 17
end position
0–9
0...9
= 5
Pb
see page 18
reset & diagnosis
b0
b1
b2
b3
b4
delete position
(No)
(YES)
factory setting
(No)
(YES)
status display
sensor status (0 … 32 … 63)
PHC test
1 (active)
0 (not active)
Note: some adjustments regarding function or operating logic can only be executed if the gate is closed
and the display shows the status „ready for operation“.
Menu structure
Adjustmets-overview
ESC
ENTER
+
–
integrated control for slider PULL TSA