- 17 -
ARS-response time
Connections and adjustments
P6
factory setting :
4
0
–
8
0–8 adjustable:
defines the response of the AR system.
(0 =max. sensitivity, 8 = min. sensitivity)
Soft stop way
Connections and adjustments
P7
factory setting:
5
0
–
9
0–9 adjustable:
determines the route of the soft stops. This results approx. from
the value shown in the display multiplied by 10. i.e.: the factory setting (= 5) results in a
softstopp length: 5 x 10cm = 50cm.
Signal lamp
• A signal lamp can be con-
nected to the terminals 10/11
(
230V, max. 100W)
.
10
11
L
N
P9
(Blininkg lamps: terminals 10/11)
o
switched off
1
4s prewarning when closing
2
4s prewarning when opening and closing
Prewarning time
Connections and adjustments
End position
Connections and adjustments
PA
factory setting:
5
0
–
9
0–9 adjustable:
used to readjust the automatically detected end positions of the gate (e.g. for safety sens-
ing edges). When the value is „0“ the motor runs to the previously learned end positions. In order to have
a shorter drive distance, this value can be extended to up to 9, which means a reduction of approx 200mm
for both final positions
This adjustment is ONLY adopted when the gate is CLOSED.
P8
0
Impulse mode:
to start the closing movement of the gate, an impulse given by impulse emitter is necessary.
1
–
9
autmatic closing
(see table):
gate closes automatically after the adjusted pause time.
Exception: If the gate is in partial open position and an impulse for complete opening arrives then the gate
opens completely and after the pause time it returns to partial opening position.
Pause time
0
1
2
3
4
5
6
7
8
9
Impulse mode
aut. closing 5sec
aut. closing 15sec
aut. closing 30sec
aut. closing 45sec
aut. closing 60sec
aut. closing 90sec
aut. closing 120sec
aut. closing 300sec
aut. closing 600sec
Operation mode
Connections and adjustments
Ausnahme
: Befindet sich das Tor in der Teilöffnungsposition und das Tor wird über einen Befehl komplett geöffnet, so wird, nach Ablauf