tousek
/ EN_PULL-TSA_03 / 25. 03. 2020
- 13 -
Pushbuttons, key switches as well as external radio receivers with potential free make contacts can be used as
impulse emitters.
P2
Impulse button
(terminals 30/32)
Buttons / switches
o
OPEN/ STOP / CLOSE impulse repetition
(fac-
tory settings): After a command give with the impulse
switch the motor starts an open or close movement. If
the impulse switch is pressed again during this move-
ment, the motor stops. With the next command, the
motor drives in the opposite direction of the last gate
movement.
1
OPEN / CLOSE / OPEN impulse repetition:
After
a command of the impulse switch the motor starts
an open or close movement. If the impulse switch
is pressed again during this movement, the motor
reverses.
• I
n this operation mode it is not possible to stop the motor with the impulse switch – it always
travels until reaching an end position. (Opened or closed position).
• for the function OPEN/CLOSE/OPEN we strongly suggest the installation of a photocell!
2
OPEN abort pause time
: With the impulse button you can only open the gate. It is not possible to close the gate
during opening, by means of the impulse button. Only when the gate is open it is possible to terminate the pause
time by giving an impulse. This causes an immediate closing movement.
3
OPEN extend pause time
: Only opening commands are accepted from the impulse button: ie it is not possible
to close the gate via impulse button. When the gate is open the impulse button extends the pause time. The gate
closes automatically after pause time.
4
DEAD-MAN:
The motor opens as long as the impulse switch is pressed – closing the gate with the impulse switch
is not possible. As soon as the switch is released, the gate stops.
For safety reasons, once the deadman setting
is selected, the radio receiver is put out of function.
• If the impulse button is set on dead man operation, then automatically also the partial opening button
will be on deadman operation. the gate will be opened by means of the impulse button and closed with
the partial opening button.
• IMPORTANT: do not carry out commissioning in dead man modus. If desired, select this func-
tion only after commissioning (see page 20).
Impulse button
(e.g. key switch EPZ 1-2T)
2 P 1
30
32
LEFT
RIGHT
Mounting direction
Connections and adjustments
P1
o
<<<--- left
:
seen from the inside, the gate opens to the left.
1
--->>> right:
Seen from the inside, the gate opens to the right.
Buttons/switches